@electricianjoe: Let me repeat 615 ft. For you metric peeps-188meters #electrician #learn #future #apprentice #ROMWEnextgen
Electricianjoe
Open In TikTok:
Region: US
Sunday 14 November 2021 03:02:26 GMT
238662
9014
232
130
Music
Download
No Watermark .mp4 (
15.07MB
)
No Watermark(HD) .mp4 (
13.07MB
)
Watermark .mp4 (
0MB
)
Music .mp3
Comments
Just me :
I'm more curious on seeing the transition from the 4/O to a 20a breaker.
2021-11-14 13:13:54
6
Lee Zack :
FYI 615ft 20 amp 120v is 3/0awg copper or 4/0awg aluminum at 2% drop he is exactly right 😁😁
2021-11-14 03:55:59
34
The Fat Electrician :
klien makes this foam lube in and aerosol can. it's absolutely amazing if you ever get a chance 2 use it
2021-11-14 04:46:19
32
Woll2.0 :
I’m sorry but did you say 4/0 for a 20 amp circuit?
2021-11-14 03:34:06
15
Jeff Hales :
How about a video on how to terminate that fiber
2021-11-14 05:14:09
5
Just a flesh wound :
Electric company has been pulling fiber in duct a long time for SCADA monitoring.
2021-11-14 03:45:45
5
redslayer23 :
I always thought they had to be separate conduit for power and fiber ??
2021-11-14 03:16:54
4
StinkyDeuce :
Why not skip the pvc and just trench toss in some URD sweetbriar (4/0, 4/0, 2/0) and call it day?
2021-11-14 04:02:39
4
Ange :
I love full color conductors. That voltage drop is a killer
2021-11-14 05:57:19
2
Rst z71 :
Joe strikes again. How deep is that 3” pvc?
2021-11-14 05:00:37
2
Joseph Belis :
Is it easier to pull with duct tape
2021-11-14 04:18:56
2
Joseph Peters :
what's the code auricle? I thought it needs the same insulation for lowvolt
2021-11-14 04:33:56
2
Nathan Reid435 :
I still get in trouble for running telco/fiber optic next to power. The inspectors don’t know electricity doesn’t run through glass
2021-11-14 16:17:37
2
Jack Snoberger :
20A circuit?
2021-11-14 03:11:22
2
Chris Barry :
fiber insulation rated for 600v?
2021-11-14 14:58:17
1
Robert :
never see your post anymore
2021-11-14 16:15:34
1
m_madden_26 :
Black and red so 240V? 240v coulda ran #1 AL
2021-11-14 04:06:38
1
Ruben Arias :
Yes but with low voltage u don’t want to put in the same conduit as high voltage because you get interference
2021-12-26 14:59:32
1
Clint Land :
Who showed Y’all how to make a head?
2021-11-14 04:36:21
1
zach :
but now that I posted that I think you are screwing with me Haha
2021-11-14 03:48:05
1
RawDawgg :
I always thought the high volt would mess with the low volt. What’s the deal there is that true ?? I’m just curious. If so what’s the exception??
2021-11-14 04:47:40
1
AG :
Great job!! TAI/EIA for pathway 40% fill? Do the branch circuit require GFP (30mA)? Thank you.
2021-11-14 04:59:12
1
zach :
I think #3 would have been plenty lol
2021-11-14 03:46:06
1
David :
Clove hitch with a half hitch and 3 half hitches is all you need to pull
2021-11-14 05:04:34
1
Kris waugh :
Curious why you ran 4/0? 1 gauge is all it calls for at 20 amps with less than 3% voltage drop
2021-12-11 18:14:45
1
Theo 🇺🇸🇷🇴🏒⚾️🏈🏟️ :
Who uses duct tape to make heads? 10 mil my guy
2021-12-05 05:23:05
1
S.tockRL :
Usually when you make up the head you want to strip the jacket off the fiber and pull it by the Kevlar inside.
2021-11-14 03:44:41
1
JMRZ :
Looks like the 90 isn’t hardly buried…
2021-11-14 05:24:28
1
Mick Butler :
Lmao that tape job! 😳
2021-11-14 05:31:25
1
Nykko Mengel :
I’ve never sent Fiber smaller than a 12, what kind was that a 2 c?
2021-11-14 05:34:50
1
Donman875 :
My boss would have made me do that myself. #companyof2
2021-11-14 03:38:13
1
Big E :
Foam soap Klein
2021-11-14 06:14:57
1
chris :
615’ pull with mule tape and the apprentice’s bullnose sounds horrible
2021-11-14 07:33:35
1
mostlikelyp :
The macro bends keep me employed
2021-11-14 08:37:43
1
Travis Sipps :
Gotta spit in there couple times too bud
2021-11-14 11:25:25
1
S1W_Alabama :
The pixies in the power cables will induce free radicals in the fiber that according to quantum physics become photons after about 1.627E12 years!
2021-11-14 12:12:41
1
Danny Larson :
so no extra clear to make life easier?
2021-11-29 06:52:25
1
@work.edits :
Was his eyes opens when he was taping that up? Jeez 😂
2021-11-14 12:23:43
1
dutysuper :
Try 5689’ 6 pull street rated pull boxes in august in phx. One of the worst pulls I’ve done. When done no cracks.👍
2021-11-29 05:45:25
1
HairMonster :
12ct fiber with BIF?
2021-11-14 03:37:45
1
brett jumper :
Never seen duct tape used but hell it worked
2021-11-28 15:48:05
1
Drop the Mike :
That bottle of lube look like it was from the Civil War! Lol😂
2021-11-14 13:27:45
1
KJ B06 :
That wasn’t a head that was a foot. 🥺
2021-11-14 13:44:47
1
Matt Cook :
i thought that anytime running lower voltage , especially something running data , you should keep it away from high voltage due to the emf ?
2021-11-14 13:50:39
1
Joe :
Hey Joe, let’s see what you ended up with for the end of that fiber? Did you just put it directly into a switch or terminate into a fiber enclosure?
2021-11-14 14:18:05
1
To see more videos from user @electricianjoe, please go to the Tikwm homepage.
Other Videos
الأغنية كاملة زي ما طلبتوها..... 🖤🦋 #وسرك_ايه #ولو_يتعاد_زماني_هعيشه_كله_انا_ليك #foryoupage #fyp #viral
🫂🤍"#حبيبي_والله_لسى_حبيبي #عبد_الحليم_حافظ #العندليب_الأسمر #متة #تصويري📷 #كفر_عويد #البارة
لكن عوض الله سيمحي مر مارأيت"
#fypシ #EGYTUBE #egyptian #arabic #arab #egypt #northafrican #masr #arabfyp #arabproblems #egyptianproblems
Холодно и тепло ❤️🩹#хазяева #хазяева2021 #2021зима #2021 #твич #elbruso #on #grove #рекомендации #fyr #for #fyp #ностальгия
"أغلق النافذة التي تؤذيك مهما كان المنظر جميلاً"
About
Robot
Legal
Privacy Policy