@electricianu: WHY WE BOND (Neutral & Ground) Explained in 3 Minutes ⚡️⚡️ #electrician #electriciansdoitbetter #electriciansoftiktok #electricianlife #electricians

Electrician U
Electrician U
Open In TikTok:
Region: CR
Saturday 02 April 2022 15:36:19 GMT
450935
14070
335
1545

Music

Download

Comments

somuchnope
Over_Your_Drama :
You almost got this correct.
2022-04-03 01:41:33
13
the_hkoop123
Eat This :
Great visual aid for that explanation. Can you make one explaining why not to bond ground and grounded at points after first means of disconnect?
2022-04-02 16:21:16
28
redsox76
Brian Korab :
Keep doing what you're doing. Electrician U is the best thing on TikTok!!
2022-04-02 16:05:31
102
ckap707
CKAP707 :
Talk about sub panels next and why we separate the neutral and ground
2022-04-03 01:46:37
50
7contractorbob3
Loal Stahlnecker :
So why does the ground need to… ground to a rod outside if the “power” is going back to the source?
2022-04-03 09:03:18
2
user7716622879682
user7716622879682 :
wrong! ground needs to be separate from neutral otherwise earth wires would be live.
2022-04-11 12:43:47
2
seemerollin97
seemerollin97 :
I'm stupid... cause I didn't understand how that explains anything. if all you need is a complete circuit, why not use the neutral in place of ground
2022-04-02 16:20:02
0
tomato_express
Jabba Covfefe :
Nice to finally see someone who knows the difference between a neutral and a ground!!! Thank you.
2022-04-03 02:51:31
3
danielmtraylor
danielmtraylor :
Question, if the power passes though the house and back to the pole. Are we getting charged for the amount of electric that passed though. Not used?
2022-04-03 00:41:18
0
sixisall2001
KevinK 💙 :
Can you also explain why we do not bond the neutral to ground in sub panels?
2022-04-02 19:23:09
2
meomy111
Roy Lemons :
then explain how the rest of the world does it without grounding the neutral? the breaker doesn't sense anything, it overheats. it's because we groun
2022-04-04 08:53:10
1
toonedram
toonedram :
I still don’t get it
2022-04-03 02:09:16
0
jason_paradox
Jason_Paradox :
Ok, u ready for this? It has been deemed a bonded neutral with a relationship to ground is a safer system.
2022-04-03 03:48:54
0
tonysmithii
Tony Smith :
Nice video. I challenge you to make one on why we don’t bond at subpanels.
2022-04-03 01:45:20
4
torel78550_t1
TikTok Main :
Then why bother with the ground screen or pole?
2022-04-22 02:34:20
0
brunoblues1
Mark Anderson :
Johnnie’s gotta come home. Lol
2022-04-21 23:36:35
0
el.paseo58
El Paseo :
This is incorrect, if hot shorts to a good ground there b sufficient current flu to trip breaker even w/o a neutral, that’s y there r ground rods
2022-04-03 00:31:20
1
lc.electro
LC.ELECTRO :
that is good what about the TT system
2022-04-02 16:22:54
1
dannysofli
Danny's of Copiague :
great clip. I have wondered this for many years.😁
2022-04-03 13:35:56
2
jamesanders95
user4033795152767 :
Great information
2022-04-02 16:05:54
1
eusten4
Eusten4 :
this might not be the case! because even in that case live wire has an indirect path to transmitter. the current flows to ground by ground wiring &👇
2022-04-03 03:21:48
2
91wolverine
Salem al Yaffee 🇾🇪 :
breaker will still trip if over current
2022-04-13 04:41:37
1
torchredmach92
Frankie B :
Good info to pass….. but you lost the layman
2022-04-02 16:19:29
1
slopcounts
Jeremy Hesser :
I work with 480 wye systems, I’ve had electricians bond ground to a neutral at the panel and call it 480 wye, when the feed is actually 480 delta.
2022-04-03 15:04:26
0