@karlythesparky: Reply to @ogbryn98 did it for the vid ⚡️ #electriciansoftiktok #electrical #sparkylife #homeupgrades #bluecollarwomen #diyproject #worker

Karly the Sparky
Karly the Sparky
Open In TikTok:
Region: CA
Thursday 23 June 2022 21:53:46 GMT
1645602
24320
1136
335

Music

Download

Comments

teaken4
teaken4 :
Just pushing the test button or something?
2022-06-23 22:13:55
286
jullianbattley
Jullian Battley :
for her next trick she will touch phase to phase on 3 phase
2022-06-23 23:32:46
562
functionaldadbod
Scott Parnell :
Neutral isn’t landed on the other end, therefore no path back to source which means no potential
2022-06-23 22:07:30
357
karlythesparky
Karly the Sparky :
I’ll pin the comment that guesses correctly how I did this ⚡️🧙‍♀️
2022-06-23 22:02:36
59
triplemm83
Trimer :
it's magic
2022-06-23 22:03:59
60
aaronpugh0
Aaron Pugh :
No path to ground
2022-06-23 22:06:14
22
nateypoo
nateypoo :
people. go youtube circuits lol.
2022-06-23 22:01:27
36
rdaviselectrical
R Davis Electrical :
I know it’s only 120v but still 😅😂
2022-06-24 17:42:18
20
hayesjj69
hayesjj69 :
Bro you ok?
2022-06-23 21:57:26
13
somopat
Somopat :
Your boots are insulated! The wire is actually live, ⚡️No path to ground.⚡️
2022-06-24 01:47:39
13
shannonscott4
Shannon Scott :
howwwww?????
2022-06-23 21:59:38
1
robbinboots
Robbinboots :
Your grounded and you completed the circuit?
2022-06-23 22:04:59
1
limes_420
zzz :
As an electrician that tool will never be used unless I have to cut a cable, now use some proper equipment and do it again
2022-06-24 15:10:40
6
killahambino
🤌 :
just tell us already
2022-06-23 22:08:33
1
vicluvin
Adogg :
When you become a Red Seal Journey Woman, the electricity is now intimidated... and no longer shocks you!😁
2022-06-23 22:23:05
41
adamd1839
Adam D :
Don’t teach people this!!!
2022-06-27 11:29:04
17
usershit60
Usershit :
fakee I have the same fluke and it has a button which turns on the red light to ensure that the battery continues to work😂😂😂
2022-06-23 22:11:12
1
alecburkhart44
Alec Burkhart :
Either a floating neutral or that white is being used as a switch loop. When she grabs the hot it energizing her but she’s not grounded
2022-06-24 01:03:30
10
coolshrimpmodz
Coolshrimp :
In this case the neutral was not connected to the panel so a multi meter would have read dead. While the probe showed its live. I did a video on this.
2022-06-23 22:49:17
4
supersaiyan1320
Popeye :
She didn’t actually touched the neutral, she put the ticker between her finger and the neutral then current tan through her making it go off.
2022-06-23 22:33:24
3
samlloyd915
Sam Lloyd598 :
Neutral wire is disconnected in a J box🤙🏼🤙🏼
2022-06-23 22:50:23
2
enter_jon
Jon :
Is the neutral terminated at the panel?
2022-06-23 22:35:13
1
andrew_bailey85
Drew :
it's reading the neutral through your finger, its not actually touching it but slick!
2022-06-23 22:39:08
1
wyatt_west01
Wyatt West643 :
perfect example of zero potential difference. if she isint touching anything grounded then her body assumes the 120v and no shock & neutral is open
2022-06-27 15:15:35
1
_fireman194
Kokopelli :
Sorcery 😏
2022-06-23 22:01:37
1
To see more videos from user @karlythesparky, please go to the Tikwm homepage.

Other Videos


About