@professorplumbofficial: Balancing a heating system #teamplumb #plumbing #plumber #plumbinglife #plumbinghacks #plumbingtok

Professor plumb
Professor plumb
Open In TikTok:
Region: GB
Monday 26 September 2022 13:48:24 GMT
48655
633
32
30

Music

Download

Comments

stevegrant26
Steve Grant267 :
should be 20deg td across each tail . with trv fully open. shutting the lockshield down and cracking a few 1/2 turns will do it but a bit rough😁
2022-09-26 16:17:41
2
broomski0
Broomski :
Ok my radiator furthest from my boiler takes around 15 mins to get hot, would this help to get it hot quicker pls?
2022-09-26 18:16:19
1
userq8q0n1onfu
… :
What if you have a massive air lock ? The pump make air ‘noises’
2022-09-28 05:18:03
0
dpak.kwr90
Deepak Kunwar :
or the proper way is to check the flow and return temperature in every rad.
2022-09-26 15:37:42
1
osabz
Sabrina :
Do you start to close all the radiators and then start doing quarter turns on each lock shield, starting from the radiator furthest away?
2022-09-26 16:00:27
2
kevgreener
Kev G :
with thermostatic valves the boiler should have a by pass or 1 rad without a thermostatic valve these often are left fully open and cause a short circ
2022-09-26 18:31:31
1
howes1960
Apple User982948398 :
You are right in what you are saying but the lock shield could be on the flow.!! Not the return 😳
2022-10-04 02:54:57
0
yorkshiretradie
The Yorkshire Tradie :
Confused. I was expecting you to balance a rad on your head.
2022-09-26 19:53:15
1
ryno176
Potstirrer :
camera could do with a clean 😁
2022-09-27 20:19:47
1
adzwil
adzwil :
I guess that was a bag down by the rad not fruity trousers?! Also “wop the heat up” 😂😂
2022-09-26 17:10:55
1
urmasellsfakebiftaslad
whosegotthelemo :
Recollection was right i think 😂😂
2022-09-26 14:04:43
2
gingerplumbs
gingerplumbs :
Balancing is about getting your 18 degree flow and return difference.
2022-09-26 17:14:26
2
darrie966
Darrie :
what's your thorts on self bleeding rad vent thing s...
2022-09-26 18:40:15
1
jjjjjjjjjjj1115
Jacko ❤️🎸🍋 :
I start by shutting all the lock shields down so all the rads go cold then start with the closest to the boiler n open it up till it gets warm
2022-09-26 20:24:28
1
lucab516
lucab516 :
Made it easy to understand
2022-10-13 20:10:08
0