@professorplumbofficial: Tiny Unvented cylinder install at a warehouse with lots of lovely speedfit pipework 🙃 #plumber #plumbing

Professor plumb
Professor plumb
Open In TikTok:
Region: GB
Tuesday 03 October 2023 18:45:11 GMT
36767
1141
45
18

Music

Download

Comments

marktradie1_imback
Mark 😎 :
Do you need qualifications to do G3 ticket? Been plumbing years but dont touch boilers never been able to touch unvented
2023-10-05 07:24:17
1
paulsolheim
Paul Solheim :
avoid the flux water invest in press tool
2023-10-04 06:33:46
5
leetaylor1982261282
Lee Taylor :
I always tee in expansion vessel on cold feed after valve before drain off. Manufactures say they prefer it there to stop water hammer. Plumbed in cop
2023-10-03 19:16:23
3
lsl_plumbing
LSL Plumbing :
Just watched that whole video and all I took from it was using the eye on the adjustable to open the stop cock, I have never thought of that 👌
2023-10-03 20:21:24
2
liverpool5979live
holty :
If room, I prefer to tee the cold into the d2 via an iso valve, for quick drain off of direct to outside
2023-10-04 17:29:37
2
__jake00
__jake00 :
Love reading all the know it alls comments 🤣
2023-10-04 11:28:55
1
beechylad
Adam Liam Beech :
Still can’t get over the fact you can use a bacho to turn the stop tap on and off 😳 tried this last week on one that was a lil stiff 🤯
2023-10-07 16:09:12
1
growupm8
Have a little grow up. :
the plastic is rank tho 😅
2023-10-06 13:50:04
1
monsterinsideme
jonseph :
I'm convinced this guy is cjrepectrical in discuse
2023-10-05 23:19:32
1
bluebulldoguk
Blue Bulldog Plumbing Official :
1st solder for the social, 2nd solder is every joint I do everyday away from camera 😂😂😂
2023-10-04 21:16:35
1
itz._.samora
itz._.sam :
what are your most used tools? basically your essentials
2023-10-03 19:01:07
1
box_fresh_
Tommy :
Would you come to Standlake to quote me for a shower pump and fit a rad?
2023-10-04 08:22:44
1
ryanm140
user9841714795703 :
Why go from 15 to 22 on mains
2023-10-03 20:07:07
1
tedmanz
Ted Man :
Where did you do your unvented ticket?
2023-10-03 19:54:30
1
admpount
admpount :
No T with drain off on expansion ?
2023-10-03 19:49:37
1
bonjames123
Bobjames123 :
Using blow lamp too close to vessel
2023-10-03 19:32:57
1
hortonater1
Kiel :
Where’s the drain valve on the vessel ? Looks like we will be out to change that to a flow through under legionella risks
2023-10-04 09:53:20
0
joe_carling
Joe Carling :
Never seen that blue stuff? what’s that??
2023-10-05 06:31:33
0
premierdevelopments
PremierDevelopments :
Whoa wait a min … ! Turning the mains back on in a tight space with the spanner end 😎 who’d have thought , top tip !
2023-11-01 19:00:40
0
clarkie7372
Clarkie7372 :
why do you not need a balance cold ? just for everyones info ......my app is watching aswell 👍👍👍👍
2024-07-19 19:49:52
0