@yycinspectormarty: New but not brand new home inspection today. Attic ventilation is critical in our climate to prevent a buildup of moisture in the attic space. #homeinspection #newhome #inspectortok #yyc #nookcrannyhomeinspections #dadsoftiktok #calgaryhomeinspector #albertahomeinspector #calgaryhomeinspection #homeinspectionhorrors #attic #attichatch #atticinsulation
Same thing was done in Regina, Sask to a lot of row houses
2024-05-06 23:15:26
0
Pamela Senft :
OMG this has become my favorite tiktok follow!! I can't even afford a house, but I absolutely love watching this 😂 not sure I want to buy a house 😭
2024-02-29 02:05:51
5
lakelifebryan :
Not sure about Calgary, but vented soffit is not allowed in Edmonton on sidewalls due to fire code.
2024-01-27 00:22:42
3
lakelifebryan :
Just seal the house properly to keep humid air out of your attic. Then you only need venting to cool your attic in the summer.
2024-01-27 00:23:42
2
R Ponto :
I love this video, thanks, for this!! Have you run into attic rain this year yet?
2024-01-27 01:03:49
2
user6204898236389 :
In the Lower Mainland, some jurisdictions do not allow vented soffits adjacent to neighboring structure depending on. This is to prevent flame spread.
2024-01-27 23:26:56
2
Roger Petersen345 :
Need more roof vents for sure
2024-01-28 00:17:57
2
Apple User799262 :
Does Calgary have inspectors that pass this?? Calgary should hold the inspectors and contractors accountable.
2024-01-28 17:40:42
2
Steelguy :
Why wouldn’t you just use vented soffit everywhere to even match aesthetically?
2024-01-27 05:44:06
2
Coopostar :
Need a gable end vent
2024-01-27 00:56:02
1
Handi_ca :
Who determines where the attic ventilation is to be installed? The architect? 🤔
2024-01-27 16:37:17
1
Dave Win22666 :
You be called the Attic King
2024-01-27 00:29:43
1
Todd :
How did it pass final inspection in the first place.
2024-01-27 15:35:24
1
Yeshue 777 :
Invisivent
2024-01-27 00:26:27
1
eff trudeau :
if the roofline is 4 feet or closer to the property line, fire code requires non vent Soffit. atleast that's code in my city.
2024-03-04 17:23:41
1
Christopher Motkaluk :
As a roofer and Sider, I have complained about this since day one it is there for fire rating no way around it. Yes the sidewall should be vented.
2024-02-14 14:26:57
1
Broken.coil :
The HRV intake and exhaust are reversed
2024-01-27 16:58:46
1
eff trudeau :
it looks like they could have done vented on one side, but the other is definitely too close to use vented Soffit. it would fail fire code inspection if they had.
2024-03-04 17:28:38
1
The_Alberican :
I laughed when siri started chirping.
2024-01-27 16:33:21
0
Chad Belyk :
looked like that light is hung upside down in the"organic growth" room
2024-02-01 14:11:34
0
it doesn't matter :
we also need to stop realtors & investors from building homes on their own with no knowledge of construction other than they fund the project and want the cheapest build price & hold the actual
2024-01-27 18:13:39
0
Robert tapson :
Non vented soffit along lot lines would be because of fire code regulations. Soffit less that 4ft from property line needs to be non vented. should add more vents on gable ends to provide more vents
2024-03-15 04:40:48
0
Carl Wilson :
My guess roofer was given venting to install along the lower 4ft of the roof but never did. City inspectors rarely look at this zero lot line issue.
2024-06-14 09:13:17
0