@yycinspectormarty: New but not brand new home inspection today. Attic ventilation is critical in our climate to prevent a buildup of moisture in the attic space. #homeinspection #newhome #inspectortok #yyc #nookcrannyhomeinspections #dadsoftiktok #calgaryhomeinspector #albertahomeinspector #calgaryhomeinspection #homeinspectionhorrors #attic #attichatch #atticinsulation

Nook & Cranny Home Inspections
Nook & Cranny Home Inspections
Open In TikTok:
Region: CA
Saturday 27 January 2024 00:05:35 GMT
52707
1828
144
83

Music

Download

Comments

bat1224906
Untrad Farming Wife :
Same thing was done in Regina, Sask to a lot of row houses
2024-05-06 23:15:26
0
clazzypants78
Pamela Senft :
OMG this has become my favorite tiktok follow!! I can't even afford a house, but I absolutely love watching this 😂 not sure I want to buy a house 😭
2024-02-29 02:05:51
5
lakelifebryan
lakelifebryan :
Not sure about Calgary, but vented soffit is not allowed in Edmonton on sidewalls due to fire code.
2024-01-27 00:22:42
3
lakelifebryan
lakelifebryan :
Just seal the house properly to keep humid air out of your attic. Then you only need venting to cool your attic in the summer.
2024-01-27 00:23:42
2
lookinaround11
R Ponto :
I love this video, thanks, for this!! Have you run into attic rain this year yet?
2024-01-27 01:03:49
2
daletrach56
user6204898236389 :
In the Lower Mainland, some jurisdictions do not allow vented soffits adjacent to neighboring structure depending on. This is to prevent flame spread.
2024-01-27 23:26:56
2
rogerpetersen345
Roger Petersen345 :
Need more roof vents for sure
2024-01-28 00:17:57
2
apple.user7992620
Apple User799262 :
Does Calgary have inspectors that pass this?? Calgary should hold the inspectors and contractors accountable.
2024-01-28 17:40:42
2
thattapingdude
Steelguy :
Why wouldn’t you just use vented soffit everywhere to even match aesthetically?
2024-01-27 05:44:06
2
coopostar
Coopostar :
Need a gable end vent
2024-01-27 00:56:02
1
handi_ca
Handi_ca :
Who determines where the attic ventilation is to be installed? The architect? 🤔
2024-01-27 16:37:17
1
davewinship877
Dave Win22666 :
You be called the Attic King
2024-01-27 00:29:43
1
toddburs
Todd :
How did it pass final inspection in the first place.
2024-01-27 15:35:24
1
yeshue777
Yeshue 777 :
Invisivent
2024-01-27 00:26:27
1
eff.trudeau
eff trudeau :
if the roofline is 4 feet or closer to the property line, fire code requires non vent Soffit. atleast that's code in my city.
2024-03-04 17:23:41
1
christophermotkal
Christopher Motkaluk :
As a roofer and Sider, I have complained about this since day one it is there for fire rating no way around it. Yes the sidewall should be vented.
2024-02-14 14:26:57
1
broken.coil
Broken.coil :
The HRV intake and exhaust are reversed
2024-01-27 16:58:46
1
eff.trudeau
eff trudeau :
it looks like they could have done vented on one side, but the other is definitely too close to use vented Soffit. it would fail fire code inspection if they had.
2024-03-04 17:28:38
1
the_alberican
The_Alberican :
I laughed when siri started chirping.
2024-01-27 16:33:21
0
cdawg855
Chad Belyk :
looked like that light is hung upside down in the"organic growth" room
2024-02-01 14:11:34
0
1fastamg
it doesn't matter :
we also need to stop realtors & investors from building homes on their own with no knowledge of construction other than they fund the project and want the cheapest build price & hold the actual
2024-01-27 18:13:39
0
user36340622
Robert tapson :
Non vented soffit along lot lines would be because of fire code regulations. Soffit less that 4ft from property line needs to be non vented. should add more vents on gable ends to provide more vents
2024-03-15 04:40:48
0
big_papa_wilson
Carl Wilson :
My guess roofer was given venting to install along the lower 4ft of the roof but never did. City inspectors rarely look at this zero lot line issue.
2024-06-14 09:13:17
0
To see more videos from user @yycinspectormarty, please go to the Tikwm homepage.