@replumb: installing a little firefighter gas shut off valve to comply with a clients insurance policy. are these going to become standard in earthquake prone areas?

replumb
replumb
Open In TikTok:
Region: US
Tuesday 07 May 2024 23:40:38 GMT
194820
3076
122
76

Music

Download

Comments

jimstettler
jimstettler :
Once that gets it a FM stamp, it will probably start showing up in code. FM is Factory Mutual kinda like UL except it is fire ratings for insurance companies
2024-05-08 01:24:41
78
simi_emergency_plumbing
Simi_valley_emergency_plumbing :
If you’re in California, it needs to be the same size as the inlet to the house
2024-05-08 05:57:05
4
stance19911
Stance :
If you use a little scotch bright or Emory cloth the paint sticks to the mega press I’ve heard the complaints already
2024-05-07 23:58:56
14
esppsd
EsppsD :
This is a far better idea than those stupid anti siphon things for plumbing code.
2024-05-14 21:52:34
0
koby.mp4
SteakQuesarito :
love how apparently there’s literally no correct way of doing stuff like this, always someone throwing out critics
2024-05-08 12:08:25
3
make.cali.red.again
Mike Honcho :
Had one at my shop but big trucks would drive by it trip it all the time
2024-05-08 16:25:09
12
zachchapel
Zach Householder :
Music choices are on point…just like the work 🤌🏻
2024-05-16 06:45:53
0
pumpingpistons
JayJay :
I installed one once. It had to get inspected and the inspector had me install a strut from the pipe holding the valve to a solid object (stud) in the wall to avoid it tripping on contact.
2024-06-21 03:50:09
0
markhedges7
markhedges7 :
where do u get the open face wrenches
2024-06-01 00:22:10
0
kevjfarley
kevjfarley :
Looks like a Socalgas meter to me!
2024-05-08 03:50:50
3
user6435901294039
user6435901294039 :
Someone at one time used the natural gas as a electrical ground
2024-05-08 05:34:15
4
olddirtymexican
OldDirtyMexican :
How’s those “auto lock” Milwaukee pipe wrench? those always interested me but seems like they would suck or som
2024-05-08 03:50:26
1
scubaman0007
scubaman007 :
you do know that the gas company service Tee is supposed to face towards the house line, where you put it does nothing.. they will d8sconnect it
2024-05-08 04:15:48
3
jimmy_fitzenya
JimmyFR :
Where’s the wall sleeve?
2024-05-08 02:15:57
1
alwayslost1234
alwayslost1234 :
so , how hard does it have to be struck to operate.
2024-05-08 03:23:15
0
eingemaischt
eingemaischt :
muss man heute "mit Wärmepumpen nicht nötig" oder so kommentieren?
2024-05-10 12:34:21
4
ohalls48
ohalls :
And for one that gas meter is under sized if you’re using 1/1/4 pipe on the house line that’s an indicator right there too !
2024-05-14 03:46:17
1
xp.382
🔪XP382🐝🎣 :
I think it should be on all gas lines no matter what.😳😳😳
2024-05-10 00:44:39
1
tuttersburner
tuttersburner :
No yellow on gas pipe? A sin?
2024-05-12 22:28:55
0
jamesreb
James Reberry :
Last few places I’ve lived in (Los Angeles) have had earthquake valves. Easy to reset.
2024-05-10 23:45:52
0
epifaniorosas455
epifaniorosas455 :
good
2024-05-18 00:46:24
0
raulmartinez4319
Raul Martinez :
😳😳😳wattt 3/4 1 inc 3/4 again in 1 1/2 hause 🤔🤔🤔🤔 is rare
2024-05-17 02:23:35
0
psycostea
PsycoStea :
Hammer Industries?
2024-06-02 04:16:13
0
bradmoreland4
Brad Moreland :
Been putting a lot of them in the commercial buildings in Oregon
2024-05-12 17:19:02
0
kaed0s
Kaedos :
I installed a fire hood exhaust and gas shut off in a residential home, elderly parents with early stage dementia. Its not a bad idea for every home really
2024-05-08 11:04:15
0
To see more videos from user @replumb, please go to the Tikwm homepage.