@worldofhvac: This was never going to work. #hvac #hvactechnician #hvaclife #minisplit #acproblems #waterdamage

WorldofHVAC
WorldofHVAC
Open In TikTok:
Region: US
Monday 03 June 2024 18:27:48 GMT
142273
2708
124
193

Music

Download

Comments

kevo_512
Kevin G :
All the installer had to do was remove the plug on that left side, and move the hose and reinstall plug on right. 🫣
2024-06-03 20:11:32
52
danielporter2012
Daniel Porter :
Drill a hole straight outside, then make some kind of cover to cover the drain
2024-06-03 22:58:17
18
reellifejesus
ReelLifeJesus :
I thought they came with pumps
2024-06-03 19:51:26
0
beanboybaby
Cam :
High voltage?
2024-06-03 21:30:21
0
ahoffmantreks
Alex :
move the drain to the left side !😩
2024-06-05 00:34:34
1
adrefrigeration0
Dwayne Doxilly :
these type of installers get more work than you the professional
2024-06-07 17:09:01
6
evilflyingmango
evilflyingmango :
Does the drain have a pump?
2024-06-03 19:44:47
0
yoyobarlow
YOYO :
Not high voltage 👀 120-208
2024-06-05 11:23:42
3
capt._morgan
Captain.Morgan9 :
Dude. Drill a 2” hole bottom right corner, it can feed your communication cable, high volt AND drain line all in one hole. Little line hide and it looks beautiful
2024-06-04 11:37:43
1
lebron75wesley
Sausage :
Hose is multi position lol
2024-06-03 20:03:00
4
tonykid1980
A-Train :
All unesassary work just drill a hole with copper pipe seal it with silicone right on the back. That mess they did causes leaks
2024-06-03 18:34:40
2
tonywalker783
tonywalker783 :
those clear tubing sucks. they pinch easily and require a large radius turn. would have been fine a solid 90.
2024-06-04 18:07:00
1
tssawyer46
user3327558642022 :
Gets better there’s a drain connection on both sides
2025-06-16 07:19:08
3
deznuza
justme720 :
I'm not a plumber and yeah I see the work and it's handyman special but I that's not high voltage. 120/220 but I understand man . 277/480 and up is considered high voltage in my field ..
2024-06-04 02:58:41
2
tobsterthetoast
Toby Jose :
they make mini spilt pumps just in case you don't have a fall, and on some brands you can change the drain side from the right to the left. I also believe that mini are positive pressure
2024-06-03 20:26:03
2
297thor
air297 :
ac has drain ports on both ends 🙈🙈🙈 oh lord
2024-06-09 00:54:33
2
edoevo8e
Eddie’s f350 :
Why wouldn’t they just follow the liquid lines and suction line out the wall outside to the unit?
2024-06-08 13:08:51
1
adrefrigeration0
Dwayne Doxilly :
wow great install
2024-06-07 17:07:53
2
rango_c10
rango_c10 :
Condensate pumps ftw
2024-06-19 23:51:00
0
jakemotta
JAKE DAVID MOTTA :
Just cut it; do a new drain
2024-06-18 22:19:01
0
btinwindsor
BT :
High voltage is a thing over 750/1000v
2024-07-18 22:39:54
0
minisplit.guys
Minisplit Guys :
This is not a good install. The drain should go straight outside
2024-06-25 17:11:13
0
user736337
user736337 :
So the new wall units don't have a condensate pump built in anymore?
2024-06-22 03:32:59
0
jsteuu
Jordan :
Looks good from my house haha
2024-07-01 11:08:37
0
rasta2700
Astro&Strormi :
They probably thought it had a internal pump inside lol
2024-06-03 22:13:24
0