@ctclimited: Meeting the right professionals in building construction is the best when choosing to build. @Kenny Okus @Tanny #conctwinnix #construction #building #engineering #lagosstate #civilengineering

Conc-Twinnix Construction Ltd.
Conc-Twinnix Construction Ltd.
Open In TikTok:
Region: NG
Sunday 07 July 2024 09:43:57 GMT
73941
2573
135
202

Music

Download

Comments

user7780637948145
Bin kategaya :
That happens only in west Africa. Shauri yenyuu. Uganda we are not completely
2024-09-30 20:44:51
0
user2880977336563
opeyemi najeebdeen 💯🥰 :
the structural and civil engineer are thy desame
2024-07-20 15:31:01
1
bullions001
bullions001 :
nice edit
2024-10-03 07:51:59
0
sarahedokpayi978
Edwin :
I think the error is the distance between each column and beam probably material
2024-07-08 05:22:34
24
gideonehijeh
gideonehijeh :
what of an estate surveyor?
2024-07-07 15:54:57
1
divine_794
Divine :
What if this failure was caused from the raw material failure
2024-07-11 14:21:40
2
jessicabwsh
Jessica :
used cement from cheaper guy
2024-08-16 13:19:59
0
dollarpo95
Arc. Dollar-po :
The issue here is the beam wide and depth isn't proportional to the spacing between the columns.
2024-07-07 18:59:36
3
jeto_c
Jeto_C :
7-10m span with 230 square millimeters columns. Weldone oooo, mr "i want it cheap" 👏
2024-08-20 09:13:08
0
vicab78
victabb2022 :
how are you sure all these people were not involved but corners were cut? my take
2024-07-07 22:03:03
3
ajideidowu7
AaRon :
many know but the money factor
2024-07-07 14:30:28
2
eng.hum
Hum :
The building was even so patient 😆
2024-07-11 06:19:11
3
iq_c0nstruction_c0mpany
IQ_CONSTRUCTION_COMPANY :
the client knows who will do it cheaper 😅
2024-07-10 07:27:57
1
north_coast_architects
North Coast Architects :
No.5 is a Civil engineer 💯
2024-07-11 14:40:02
1
coremagma
Core Magma :
it's not just about the span but it could also be as a results lapping in a critical zone looking at where the beam failed
2024-07-08 18:12:38
2
wuodaboke581
PAPA OJ :
Always, get the span length and divide by 325( L/325") . get the deflection. Design . D= 5wL⁴/384EI.
2024-07-11 16:42:46
4
choppa_wr
CHOPPA😈👻 :
I know someone cheaper 😂😂
2024-08-25 08:44:13
1
user416159465
user416159465 :
you didn't mention m&e engineer
2024-07-07 18:45:57
3
omojesu736
Sammy :
my brother you need the soil test of the land
2024-07-07 21:27:15
2
peritum_engineering_serv
Victor K. :
What if after investing in your project and it got burnt due to electrical failure.I don't know why u guys always exclude MEP Engineer.
2024-07-10 09:04:08
2
inspiremidway
Inspirational-way :
So there's no need for MEP Engineers abi?
2024-07-07 21:34:44
1
lindaemefa272
lindaemefa272 :
sure
2024-07-13 18:20:36
2
fcprp
FCPROP :
Intercolumn intervals too wide. Columns poorly designed
2024-07-08 21:13:40
2
kaseriousgroup
Kaserious Group :
den go hear!!!
2024-07-20 20:41:12
1
engr..tom
Engr. TOM :
but where do you put a MEP service engineer
2024-07-18 23:43:22