@love2hvac: Great Question! Why do some people have few TXV failures and some have many? Several reasons! They have been around since the days of Willis Carrier so it's not new technology. The big issue started around 2013/2014 when a major compressor manufacture used a rust inhibitor that reacted with POE oil and it gummed up TXV's. This led to class action lawsuits and LOTS of TXV failures!!! It then just became a shortcut to replace the TXV then a habit that was taught to the people entering the trade. Bad habits are easily learned. Then we have improper diagnostics. People condemn them based on suction pressure alone. Next is contamination such as oxidation, dirt debris, copper shavings, foreign matter. Improper vacuum leaves moisture that can freeze inside a system but causes acid with low oil. that eats away copper that can clog the TXV or the acid can directly damage the TXV. wax can even be in the system. overheating from brazing can damage the superheat spring, the metering pin, the seal inside or the lower head. Overheating the suction side can over pressure the sensing bulb and damage the lower head. The transmission tube can run a hole when it's not properly mounted. and they can just rust out. these are the main reasons.#hvac #love2hvac #TXV

love2HVAC
love2HVAC
Open In TikTok:
Region: US
Tuesday 20 August 2024 04:27:26 GMT
15529
700
24
97

Music

Download

Comments

297thor
air297 :
24 years doing hvac i only had 2 txv fail on me🙈
2024-08-20 14:49:03
4
johnnycold
Johnny :
Everybody thinks that heat pumps are also a new thing they’ve been here since the late 1800s
2024-08-20 04:45:56
3
a_frayed_knott
kent brown :
my favorite contaminant was a rock. thankful it was in the liquid line. landscapers graded before the condenser install. somehow got a pebble in it. ran fine after I removed the pebble. 😮‍💨
2024-08-20 05:04:05
2
marklewis1081
M@rk :
Sir you're doing the Lords work.. say it louder for the installers and the parts changers in the back
2024-08-21 20:28:27
3
zeala2020
Zeala2020 :
I can’t tell you how many times that I have seen pistons installed backwards or with condensers changed with 410 and old r22 pistons left in the system.
2024-09-06 15:38:48
1
thecoolestair
THE COOLEST AIR :
If its JCI, it's the TXV screen 🥺
2024-08-22 02:39:31
0
deanstilly
Dean :
Exactly
2024-08-21 12:08:48
1
texashvacguy2022
George :
In my 38 years only a handful of expansion valve failures, if truly defective it was usually the head. GE/Trane had many txv failures, killing compressor.
2024-08-25 13:59:58
2
floyd_ross
user1994214269478 :
Just use a piston, txv's fail, for whatever reason
2024-08-21 15:08:33
0
juliosaez4th
Julio Saez :
You helped me with my trouble shooting final thank you sir
2024-08-22 03:40:12
1
olbenny22
olhawthorne96 :
And speaking of foreign debris I wish I would have taken a picture of 3 pieces of scroll plate in the suction line right past the blown up compressor😂😂 10 years in and that was a first!
2024-08-21 17:50:58
0
terrible.cook
TerribleCook :
Just strap the sensing bulb to the liquid line and it’ll always run like a piston! Lol!😂
2024-08-21 22:05:00
0
wesroberts3
Wes Roberts :
Thank you, brother, I use your videos to help teach my two younger sons, Especially your TXV related videos ,thanks again
2024-08-20 14:32:52
1
krendoris
Krendoris :
zerol ice is a good combatant to the inhibitor issue 💪
2024-08-21 23:47:19
0
quikxotic.eng
Polaris :
liquid and suction line filter dryers,big ones
2024-08-20 05:45:41
0
olbenny22
olhawthorne96 :
But if the system is under warranty and the screen clogged with debris before the txv. Are you going to just clean the screen or replace the valve while you are there? Both take about same time
2024-08-21 17:49:34
0