@mslifeasasparky: Always wire the bulk of cables back to the fan iso when bathrooms involved. Much easier in ny opinion to connect it all up 👌🏻🙌🏻. #fan #bathroom #light #switch #click #mattblack #black #monday #sparky #selfemployed #electrician #tradesman #electriciansoftiktok #keepgoing #ms #blowthisup
Fan switch above the door. Next to switch is gonna cause confusion.
2024-09-24 12:40:05
45
Letslaugh :
Where’s the inline fuse for the fan?
2024-09-23 17:51:59
8
hilton :
Sleeving should be between 30-70% of the original color as per regulation 514.4
2024-09-24 11:56:56
3
Jack_Paxman :
Pretty sure there’s not actually a regulation height for the fan iso as it’s for maintenance and not general switching, so here, above the door or low level is all fine. Just a matter of preference.
2024-10-13 08:36:28
1
LUMOS Electrical Services :
You can get a switch with a fan isolator and fuse carrier in all of the click range. You should always fuse the fan down to 3A as requested by the manufacturer. Just a heads up as I know the NIC have
2024-10-20 19:43:46
1
kevlar :
ventilation regs require the fan to be on. therefore iso high level. I don't give the customer the choice. it is only for maintenance.
2024-10-01 15:22:44
1
ShyTalk :
I use click minigrid and put them both on the same faceplate
2024-09-24 09:16:41
5
demoz1989 :
Where's your fuse?
2024-09-24 15:16:00
1
Sonny T :
Can get a light switch and fan iso in a grid plate have it all in one back box
2024-09-24 18:03:19
2
DanMc :
All in one box , 3gang switch swap out two switches for the fan module 👏🔥
2024-09-24 15:40:05
6
Dave Browning :
Where you get that sleeving from? 👀😂
2024-09-23 20:53:20
6
Simple_life :
sfs as fan should be fused to 3 amps, then a 2 gang switch
2024-09-24 19:01:34
1
Ian F :
how would you wire in the boost from the switched side of the light?
2024-10-06 21:11:01
1
MartinW86 :
Click do them combined in a single plate 3mod :)
2024-09-25 20:03:59
1
jabs :
Can you do it like this with a humidistat
2025-01-27 17:01:29
1
Bakz_17th :
Isolator top switch bottom
2024-10-16 00:24:12
2
DOON ELETRICAL AMARU LONDON :
good job 👍
2025-01-22 19:49:39
1
l4ngy17 :
Click deco would fit nicely on a single plate
2024-11-24 11:54:18
1
Stu Country :
is no one else gonna mention the sleeving 😂😂😂
2024-09-26 12:46:48
1
Safesparx Electrical :
Have always done iso in line with top of door frame above switch
2024-10-18 19:09:37
1
Jaz Man Take My Blues Away :
Literally use a double light switch
2024-09-28 19:25:31
2
Lingdale71 :
I’ve always placed fan isolators high level as they not used very often. Also stops the wife switching the wrong switch in the dark.👍
2024-09-24 16:41:31
3
user828384828383sym :
always do mine like that
2024-10-05 16:26:03
1
Torquay_Riders :
3 gang plate with fan iso mod and 1G switch mod would look neater
2024-10-16 09:34:20
1