@sang_sang142: #semuaorang #fyp #viraltiktok

Sangsang Hijisalapantilutilu
Sangsang Hijisalapantilutilu
Open In TikTok:
Region: ID
Sunday 12 January 2025 06:58:47 GMT
206
8
0
1

Music

Download

Comments

There are no more comments for this video.
To see more videos from user @sang_sang142, please go to the Tikwm homepage.

Other Videos

The following updates are a must know for anyone waterproofing atm 🦾 Letss Gooooooo AS 3740 2021 clause 4.8.5 Where the extremity of a shower area is located within 200 mm of an exit from a wet area, it shall: (A) be an enclosed shower area as defined in Clause 1.3.31. (B) have one of the following: (i) A waterstop that finishes a minimum of 5 mm above the finished floor level, under the shower screen. (ii)A hob at the extremity of the shower area. (iii)A step-down of minimum 15 mm from the finished floor level at the extremity of the shower area. (C) have a vertical waterstop where the shower screen abuts the wall. AS 3740 2021  AS 3740 2021  Clause 4.9.2 Protection of door frames and architraves The requirements for protection of door frames and architraves are as follows: (a)Timber door frames shall not be embedded into the tiles. (b)There shall be a sealed gap of a minimum of 2 mm between the door architrave and the floor. (c)The underside of the door jamb and architrave shall be treated to resist moisture. #siteinspections #victoria #Australia #leaks #plastering #propertyinspections #propertyinspectionmelbourne #buildinginspection #building #bathroom #houseinspection #carpenters #renovation #vba #waterleaks #buildingandpestinspection #builders ##extension #defects #plumbers #roofing #carpentry #building #builder #victoria #newhome #cracks #defects #Australianstandands #melbourne #plumbing #newconstruction #homeinspection #mould #standards #tile #waterproofing #membrane #bricklayer #vba #compliance #waterstop #bathrooms #leaks #buildingtips #as3740
The following updates are a must know for anyone waterproofing atm 🦾 Letss Gooooooo AS 3740 2021 clause 4.8.5 Where the extremity of a shower area is located within 200 mm of an exit from a wet area, it shall: (A) be an enclosed shower area as defined in Clause 1.3.31. (B) have one of the following: (i) A waterstop that finishes a minimum of 5 mm above the finished floor level, under the shower screen. (ii)A hob at the extremity of the shower area. (iii)A step-down of minimum 15 mm from the finished floor level at the extremity of the shower area. (C) have a vertical waterstop where the shower screen abuts the wall. AS 3740 2021 AS 3740 2021 Clause 4.9.2 Protection of door frames and architraves The requirements for protection of door frames and architraves are as follows: (a)Timber door frames shall not be embedded into the tiles. (b)There shall be a sealed gap of a minimum of 2 mm between the door architrave and the floor. (c)The underside of the door jamb and architrave shall be treated to resist moisture. #siteinspections #victoria #Australia #leaks #plastering #propertyinspections #propertyinspectionmelbourne #buildinginspection #building #bathroom #houseinspection #carpenters #renovation #vba #waterleaks #buildingandpestinspection #builders ##extension #defects #plumbers #roofing #carpentry #building #builder #victoria #newhome #cracks #defects #Australianstandands #melbourne #plumbing #newconstruction #homeinspection #mould #standards #tile #waterproofing #membrane #bricklayer #vba #compliance #waterstop #bathrooms #leaks #buildingtips #as3740

About