@heavy_haul_n_fool: Where are all my electricians at ? When I get this all wired up, it won’t turn on the light. I’m not sure what’s going on. #Home #homeowner #electrician
make sure the bulb in the light fixture is dimmable
2025-02-24 18:26:17
12
Michael :
Are u sure that’s a neutral, is the bulb good, did you verify 120V at outside junction box, how did you verify line and load at the switch
2025-02-25 02:51:51
1
Paul Tassin :
did you add a pigtail to the neutral, or is that the neutral coming from your light?
2025-02-25 03:42:33
1
Samwise :
I've never worked on a trailer house but do have 120v at the porch light? vevor has a volt meter if you don't own one yet
2025-02-25 03:34:26
1
Notification :
You need to have a dimmable bulb for a smart switch
2025-02-26 14:13:20
4
Brian | Cybersecurity+Wireless :
Dimming switch with non-dimmable bulb? Throw an incandescent bulb in socket to test thar quickly.
2025-02-25 04:22:51
1
Dick :
Non-dimmable bulb?
2025-02-24 21:37:35
1
Otrmickey350 :
Someone comment on mine when answers come in. Also curious
2025-02-24 18:17:20
1
Joseph Rendino :
Neutral and shared ground
2025-02-25 02:15:35
1
natedvx0321 :
If it’s a smart dimmer that bulb might not be dimmable. Check all your wires with meter not a tick tester make sure you know which wire is providing 120 those non contacts can lie
2025-02-24 19:40:18
0
Tyler Cain :
If you done it with the circuit on and didn’t hook it up ground then neutral then hot you smoked the switch, or the bulb isn’t dimmable
2025-02-24 21:58:33
1
CoppGWill :
Led bulb
2025-02-25 05:39:40
1
THE_GG :
Is the light switch compatible with LED lights? Some switches aren’t compatible
2025-02-28 15:53:51
0
williamcrouse830 :
The switch is not compatible with the light run into that situation all the time in California
2025-02-25 02:48:16
1
BIG D :
Jump the line and load the led lamp May not be compatible with the dimmer switch
2025-02-24 20:03:19
1
bobwieser77 :
It’s the light bulb more than likely
2025-02-25 01:00:32
1
Ryan :
With it being a manufactured home, is the "hot" made up inside the light fixture? Most of the time the power is ran straight to the light then the wire leading to the switch acts as a jumper to switch
2025-02-24 18:27:06
1
Brett :
Non dimmable bulb
2025-02-24 22:30:59
4
Tumbleweed98 :
Sounds like a lose neutral. If you got a multimeter check voltage on the load hot a neutral. Some use the white as a switch leg even though it’s not supposed to.
2025-02-24 20:45:55
2
Tuckker :
A meter with tell you everything you need to know
2025-03-17 20:45:06
0
To see more videos from user @heavy_haul_n_fool, please go to the Tikwm