@mark_decola: Trying to wrap up the details! #military #generator #militaryequipment #dieselgenerator #willitrun #militarylife

Mark DeCola
Mark DeCola
Open In TikTok:
Region: US
Wednesday 21 May 2025 03:07:17 GMT
1706569
133458
1677
1075

Music

Download

Comments

davemakestiktoks
DaveMakesTikToks :
Dear Universe, please bring these posts to some retired/bored military generator technician so we can solve this GD riddle!
2025-05-21 05:23:14
459
hugh_janis231
shi :
algorithm must love me or sum
2025-05-21 03:14:30
8348
devon_k8
Devon K :
Maybe you just can’t switch between 50 and 60 while it’s running?
2025-05-21 04:20:43
490
anon112324537
anon112324537 :
that knowledge of finding out houses run on 60hz...hz me greatly
2025-05-21 03:16:24
557
rockpaperscissorssound
Zach :
engine speed is what dictates hertz. If it is running at 1500rpm then it will be in the 50hz range. If it’s running at 1800rpm it should be in the 60hz range. Flipping the switch mid run isn’t going to change that. Turn off switch then restart.
2025-05-21 03:59:40
488
jsmalls54705
jsmalls54705 :
Those gauge could be bad put meter into outlet and check hz
2025-05-21 03:24:18
145
xjake6996
xjake6996 :
No one sent this man the -20 technical manuals for this generator yet? They are unclass documents.
2025-05-21 03:37:08
249
lilpoocraps
lil poo c raps :
my two must watch shows right now: the last of us: Season 2 the last generator: Season 1 🤣
2025-05-21 03:58:50
744
wafy_kamaly
WafyKamaly :
budak Malaysia mane? masukkkk
2025-05-21 03:50:34
57
madmacccdaddy
MadMacccDaddy :
I always think I don't know enough to do something like this, then realize the guy doing it just learned America runs on 60Hz
2025-05-21 11:04:13
190
stes200
stes200🇬🇷☦️🫸🏳️‍🌈 :
it's 6 in the morning and i must get ready for school and I'm watching this in the toilet
2025-05-21 04:19:49
179
alexmillerphoto
Alex Miller :
Holy cow I’m early 🔥
2025-05-21 03:11:36
385
cottonwood_outdoors
🐿 🦌 🦆 🦃 🎣 🕊 :
i thought we were done 😭😭
2025-05-21 03:19:12
314
hansjansen781
joepie56 :
change the 50/60 hertz switch
2025-05-21 09:09:23
19
iam_lem
LJ :
Locked 🔒in from day 1 in 🇹🇹
2025-05-21 04:25:36
137
jamesjr071
jamesjr071 :
To early to read the suggestions 😔
2025-05-21 03:15:55
110
yatich032
Noah Ritchie :
after Scrolling a million times waiting for this part
2025-05-22 05:06:09
5
thornspike
Thornspike the Radical :
Hey that volt selector switch only changes what the gauges are looking at be it leg to leg or leg to neutral. I highly recommend never ever turning the selector switch while running or you may let the smoke out of it.
2025-05-21 03:58:58
18
rileywoodhouse74
Riley Woodhouse :
Hey boss I think your range for the multimeter needs to be at the 20k position. At the 200 position the .4 would be almost equivalent to 3k maybe more. Just a thought.
2025-05-21 04:04:12
29
joshcissungrown
JoshCissungrown :
Research =top comment lol
2025-05-22 04:13:50
7
omaarr._h
OMAR :
thanks for the algorithm
2025-05-22 17:07:12
6
manyhospital
ManyHospital :
My biggest fear is that he finally gets the generator running, what will I do then?
2025-05-21 07:35:41
13
dratiant
Josh Scofield526 :
Maybe the switch is bad?
2025-05-22 23:14:33
5
To see more videos from user @mark_decola, please go to the Tikwm homepage.