@shotscar_is_back: welp, system is kewling! #shotscar_is_back #kewling #hvac #acrepair #drain #drainrepair #furnace #furnacerepair

shotSCAR HVAC
shotSCAR HVAC
Open In TikTok:
Region: US
Wednesday 11 June 2025 17:42:07 GMT
49296
2812
56
56

Music

Download

Comments

don_juliog
Julio Gonzalez :
Who ever says it needs a p-trap needs to learn that a gas unit has positive pressure. An electric unit has negative pressure. which is why it’s not necessary to add a p-trap on a gas unit you add a ptrap on an air handler 🤦🏻‍♂️😂
2025-06-12 03:07:25
52
pinkitystinkity
Noooooova :
No ptrap?
2025-06-11 18:13:30
5
kolocho58
kolocho58 :
Good thing u install float switches but no trap🤦🏻‍♂️🤦🏻‍♂️🤦🏻‍♂️really 🤦🏻‍♂️🤦🏻‍♂️🤦🏻‍♂️
2025-06-11 19:36:57
8
challisj
challisj :
No trap, vent, ball valve? What in the world
2025-06-11 22:47:26
0
kharshyy
kharshyy :
No trap?
2025-06-11 17:59:32
1
tinman19858
Teddy :
Don’t need a trap, because the coil is on the positive side of pressure. If it were an air handler, you need a trap. I usually put a clean out tee and a vent tee though, in an attic.
2025-06-12 05:05:39
1
user4560306608501
BRINCOLINES GALAXY :
No ptrap and no razon for 2 flow switches wow
2025-06-11 19:03:39
0
nochilladam1
Adam Smith :
Cmon scar. No T 🤦🏽
2025-06-12 03:50:33
6
cjcastro84
🇸🇻 OGcastro84 🇸🇻 :
why not cap the pipe off the emergency drain pan and add a pan switch?
2025-06-12 08:56:00
3
kris22902
kris22902 :
How are you ever going to blow your drain out?
2025-06-17 00:17:31
2
b.from.oklahoma0
B.from.oklahoma :
I don't have a float switch in my pan. but i have 2 drains. the main drains out back of the house into the rain gutter drain. the secondary drains to front of the house by the front door. so if you see water dripping by the front door you know there's a problem 😁.
2025-06-13 06:15:55
1
chieb6
Chieb6 :
Why no clean out
2025-06-12 01:50:27
2
user007273411
JoseGodsFavorite :
Nice
2025-06-12 00:47:03
1
alexfranco685
Meditation :
No p-trap or vent for the main drain ??🤔🤔🤔🤔
2025-06-12 04:53:50
1
profalchemy
profalchemy :
Did you nut those wires in the blower dept? 👏👏
2025-06-14 19:25:55
2
hvacdaddy101
Breezy :
You can see all the super techs not knowing anything about drains and how they work lol good video brother!
2025-06-12 06:26:35
1
poppledungon
0000000066 :
love the videos
2025-06-13 10:10:02
1
chipstone1
Chip Stone :
No P-trap needed on furnace!!! Texas is a no no but I understand what you’re doing!! Makes sense
2025-06-12 03:41:38
0
briansharp357
briansharp357 :
where's the secondary drain cause some places require it by code
2025-06-11 20:52:41
1
luke.roberts0
Luke Roberts :
Bro your videos are the best. Keep doin them. You give excellent advise and how to on everything
2025-06-12 22:44:33
0
cesarfig.420_05
6.2cesar :
My man did u test them after installing them , had 2 come out bad new from box this week
2025-06-14 03:16:51
0
djmaddom209
Djmaddom :
so we never heard of a drain pan switch
2025-06-19 05:43:29
0
hunterharrell91
Hunter Harrell :
I run the drain to the pain in out to a carport or porch where if they see it dripping, they know to call someone.
2025-06-15 02:16:01
0
coolwater01
H. H. :
trap that float switch 👍
2025-06-14 02:02:12
0