there is too much oil in the sistem, the tank should only be full when lowered, if it's full when the piston is up, then it has no space to drain when you lower....that's why it's lifting instead of lowering...
2025-09-11 06:17:12
121
olcountrymechanic :
those are JIC fittings need no sealing tape although tape wont hurt
2025-09-27 13:46:04
0
Kyle Sopaz :
NO TAPE!! It’s a female swivel, it seals on the internal taper.
2025-09-11 03:14:09
400
️ :
Mom my shows on again!!!
2025-09-11 03:04:08
731
Anthony Kuhn545 :
Flip the cylinder lines around
2025-09-26 18:54:53
2
Ryan :
The reservoir
2025-09-11 15:56:36
177
Kevin Shipes :
to much military has to breath and piston seal could be bad
2025-09-27 15:15:36
0
lumpar87 :
I'd say either a bad seal in the cylinder or it isn't supposed to power down and it's hosed backwards. You could reverse the hoses to test that.
2025-09-11 03:24:47
61
Mike C :
the piston should be down before filling it. it should self bleed by working it up and down
2025-09-11 03:40:22
111
Adam Kastner :
that system should be pressure in one direction only. either the valve is backwards or the pressure and return lines are reversed. try swapping the lines that go to the cylinder.
2025-09-11 04:12:46
7
Derrick :
With haven’t that cylinder extended like it is your over fulling the tank with fluid lift the bed up crack the top of the tank and lower the bed it will push fluid out but at this point your at proper level
2025-09-11 03:55:13
121
cwood20100 :
Very possible that cylinder is leaking internally through a bypass
2025-09-11 03:45:49
37
Quailman101_Jr :
Disconnect to rod end of the cylinder so you can move it in and out without moving the bed. You can also hook up 5k psi gauges to the cylinder hoses to see where you get pressure. If you get full pressure on both sides and no movement in the cylinder than it’s bypassing the piston seal. Also the system will self bleed air
2025-09-14 08:17:18
1
Daniel Estrada :
If the PTO is engaging and the piston is not moving, that means it has interna bleeding, must be a bad seal.
2025-09-11 03:20:47
142
Tyler091500 :
rule number 1 never skip a Mark DeCola video😉😁
2025-09-11 03:37:25
20
King140002 :
2025-09-11 04:20:48
403
kyle gibbs :
it almost seems that the up cable is not adjusted properly, but the down cable is. not sure if it is the same cable or not
2025-09-11 03:25:26
11
Dale Lucid :
thought if the reservoir is full and the cylinder is full where is the hydraulic fluid going to go when the bed is down?
2025-09-11 08:43:15
9
T么JACKFROST会 :
Lowkey my favorite TikTok series(creator) 😭it’s so good man keep it going
2025-09-11 13:00:59
3
《☆Twister☆》 :
My favorite series is on again!!!
2025-09-11 03:11:09
11
Jaume Ferrer :
brother just tape a conical fitting
2025-09-11 06:37:52
12
Jason Watson :
Too much fluid in the system now.
2025-09-11 13:48:26
10
5.9gopher :
Hey Man i didn’t realize you own or ran MDDP performance I run their cat filters on my Cummins all the time
2025-09-11 04:07:32
5
KANE MEAD AND MORE :
try swapping the lines? if you're power down doesn't work not an issue right? still have power down.
2025-09-12 01:47:39
2
To see more videos from user @mark_decola, please go to the Tikwm