@yycinspectormarty: This one is for all the Carpenters and Framers. Will this pass for a whole in the joist? #nookcrannyhomeinspections #carpenter #fail #newbuild #buildersoftiktok
1/8” of webbing is the minimum distance to leave from the bottom or top of the joist. (Trus Joist). Directly from the specifiers guide for hole sizes.
2025-09-25 23:43:40
5
Raymond Dunn :
Joist manufacturer spec is 1/4”off the cord
2025-09-25 22:46:19
21
chrisgee5659 :
where is the slope factored in
2025-09-25 22:12:14
4
mikemackenzie10 :
That is the direct fault of the inspection authority and will never be fixed and they are never held accountable
2025-09-25 22:22:52
4
…. :
You should look at the specs of the joists. Most of those are 1/8” from the flange
2025-09-25 22:30:32
4
kristian_niels 🇨🇦 :
What the hell kind of joist is that? It looks like osb?? 😬😅
2025-09-25 23:41:35
4
Jim :
I don't see what the problem is. The holes are within spec for an i-joist. There's absolutely nothing wrong with this, they're engineered to handle penetrations like that.
2025-09-25 23:58:50
3
David Hart :
I'm a sprinkler fitter and I was always told center 3rd as a rule of thumb to be safe
2025-09-25 22:12:18
2
Scott Eveland :
i still strugle with the fact the wires are run together in one hole 3 max no more then 2 feet in contact
2025-10-18 00:22:45
2
Terel :
I believe they can be within an 1/8” of the bottom cord.
2025-09-26 00:09:01
2
Robfromcalgary :
where the hole goes is mostly determined by required slope. sometime middle of the joist isnt possible
2025-09-26 12:54:48
1
Craig Egolf :
😏😏😏😏😏😏😏
2025-09-26 08:40:19
1
jamescrowe52 :
I know what you’re saying but waste and vents have to be graded. Electrical could have easily been bent to accommodate. HVAC are always the ones to cause the problem, they chop and work to their convenience.🤙
2025-09-26 03:04:25
1
shepp :
plumbing drainage needs a fall. impossible to stay center and get proper fall
2025-10-19 21:41:16
1
John Yellow sun :
Isn’t there knockouts for pipes n wires
2025-09-25 22:41:39
1
Amanda :
if we need so many things to go in and around joists then maybe the standard walls need to be bigger to accommodate them. that way we still have our 8' ceilings with lots of room for "stuff"
2025-09-25 22:10:27
1
DBACKSTER :
FAIL it’s scary out there ! Keep doing what ur doing !
2025-09-26 14:50:58
0
Eugene Philip Brown :
the electrical should have failed as they have put to many wires in one hole
2025-09-28 04:14:23
0
fjt4ever :
In Canada, all of our TJ’s come with knockout holes for placement they’re even marked for you
2025-09-27 13:46:23
0
jds122567 :
yet another inspector who doesn't actually know specs on things. The i-joist can be cut anywhere top to bottom of the joist, but need to be a specific minimum distance from bearing based on hole diameter. Some manufacturers do require a minimum distance from the chord, but it's usually only an ⅛". You don't need to "try to be in the middle"
2025-09-27 12:29:25
0
Jack :
No one uses three inch drywall screws it’s ok !!
2025-09-26 22:46:38
0
troy parry :
Weyerhaeuser says leave 1/8” minimum of web above and below Flange. Centered is preferred, but this is acceptable.
2025-09-26 21:01:34
0
josiebell173 :
plumbing has to pitch to work can't run all center
2025-09-26 19:10:21
0
jungle :
Fail
2025-09-26 18:14:05
0
trophyboat :
In Nj it’s an 13/4 from bottom
2025-09-26 17:17:42
0
🇨🇦 Yan 🇨🇦 :
A hole in the joist web can be made 1/4" from the top or bottom flange. That said, actually in the center of the web is preferable.
2025-09-26 15:11:38
0
Artie :
Fail took all the integrity out of the eye Joyce
2025-09-28 21:24:39
0
user5395186383847 :
You might be wrong depends on spec sheet of joist but most of you can cut the whole center out if your the right distance
2025-09-26 14:32:06
0
The Ugly Truth 🇨🇦 :
pass.. you can take out all the plywood between the 2×3s unless you are within 2 feet of the ends.. I do believe
2025-09-26 14:10:16
0
johnstemarie :
Need slope
2025-09-26 14:10:03
0
nate D#GGG :
it all depends on thw specs of the joist
2025-09-26 13:32:16
0
Cadazz :
Fail , we need more accountability in this county
2025-09-26 13:24:09
0
Cow Girl _360 :
It’s not going right thru tue joist. It’s ran thru a hollow space via plywood. But I wouldn’t call any of that a joist.
2025-12-26 09:15:29
0
Fusion430 :
They have to be a certain distance from the end of the joists also
2025-10-22 15:57:36
0
Portbill :
Bottom of drilled hole has to be no less than 2" from bottom of joist
2025-11-19 13:01:27
0
chrisredd42 :
There is nothing wrong with this. Look at the spec book.
2025-11-09 21:50:59
0
Greg Horne :
A hole that size as long as they don’t cut into the joist they’re fine
2025-11-07 04:16:26
0
user1935309153122 :
How many years before all these houses fall apart? Seriously with liberals big push we are going to see substandard work. BC condo crisis all over again. I live near a new subdivision being built, there is literally people working at 11pm. Piece work, taking in so much work rushing from house to house, just throw it together move to the next one get the numbers up.
2025-11-01 14:00:50
0
handyman6599 :
Pass if within 6 inches of a wall. Fail if not
2025-11-24 01:51:29
0
ChrisV364 :
Its okay per manufacturer, just dont cut or notch the chord. Middle not required on these bruh
2025-11-01 13:35:34
0
Sean Nienaber :
what about the knockouts for ventilation in roof designs ?
2025-10-31 10:10:34
0
matthewconrad2021 :
Pass as long as they stay in the web
2025-11-17 05:08:51
0
user6968201410816 :
apparently, u can cut a hole 2 ft out of the entire web for ductwork. hard to believe but passes
2025-11-24 15:12:26
0
bobskygoot :
You don’t get to decide what’s acceptable. The manufacturer will have engineering specs which you can download. Having read at least 20 of these specs those would most likely be fine. You can also put huge holes in these from flange to flange.
2025-10-18 01:30:02
0
Scooba Steve :
fail
2025-11-27 03:13:37
0
13 Spades :
what joists are these? I'm a gasfitter and have been running lines at the bottom of the webbing for the last 10 years, all pass, also plumbing drains need to grade 1/4" per foot, how are they supposed to grade if this is the case? again maybe it's certain joists?
2025-10-17 22:53:38
0
Pat :
Fail
2025-10-13 14:08:53
0
Charley :
1/3 from top 1/3 from bottom hole can only be 1/3 size of member. When you look for problem you will always find one
2025-10-11 15:13:04
0