@mahama_tahiru: #ecg #eletrician give us one reason!!!@Electricity Company of Ghana

⚡️CurrentCareElect.💡
⚡️CurrentCareElect.💡
Open In TikTok:
Region: GH
Friday 17 October 2025 10:18:15 GMT
78936
1566
67
18

Music

Download

Comments

joshuaayayi420
Joshua Ayayi :
Copper resistance is higher than aluminum, this is done to prevent fire out break
2025-10-18 11:28:47
0
fredcrash960
Fred Crash :
my bro i always think about that if Aluminium both out and to the mainswitch have to be Aluminium,if they think copper consumption is higher then why
2025-10-20 08:57:54
0
joesalam375
joesalam375 :
chairman they've taken the copper for their business
2025-10-17 15:12:07
1
gyamfiserbeh
GYAMFI SERBEH :
that is wrong you should report that to the nearest office
2025-10-19 12:11:20
0
nanafobi12
Nana Fobi 🙋‍♂️😎😍 :
To wake the work neat 👍👍👍
2025-10-17 13:18:35
1
king.zion54
TK Electrical :
brother ask again ooo i question them about it
2025-10-19 15:43:04
0
919basitelectricals
Basit electrical :
Just to prevent meter damage
2025-10-18 08:58:26
0
afriwus.electrical
Afriwus Electrical works :
hmmmm
2025-10-27 11:58:03
0
kwa5me
. :
secondly the contractor most of them don't pay their boys well so the sell some for survival. and they take some to the office for retired material report
2025-10-17 14:58:13
0
dhiqghad
Rocz electrical ingeneering🛠 :
It’s just to avoid illegal connections
2025-11-13 20:02:42
0
sarfokantanka99
Nana Sarfo Kantanka :
This new meters are coming to help us to reduce the cost of 16mm
2025-11-12 12:58:25
0
ataankpa_waves006
Ataankpa_waves006 :
We are now doing this because that’s the new standard the board presented to us. And it’s purpose is yo stop illegal connection when you run out of prepaid credit
2025-11-16 23:51:07
0
officialrahama7
First Lady :
😂😂😂
2025-10-17 11:08:22
0
sammy54572
Oko - Adjetey :
Edey shock me self bro.
2025-11-14 12:55:20
0
dbrown123_7
Dbrown :
ECG doesn't do their work like that their law is that straight service from the poll into the meter and the load side to your circuit breaker, but if your distribution board is in side they'll join it with the 25mm aluminum but removing the copper from inside your room. hmm ECG doesn't approve that rather the people who are installing the meters are going the wrong thing 🤔
2025-10-17 13:28:31
1
nanna.young8
Nanna Young :
next time fix a servce cutout or breaker for the output beside the meter so your load will end at that point
2025-11-12 08:04:24
0
kwa5me
. :
because the transmission lines( the four wires on the ECG poles) are made of Aluminum. so in order not to create carbon powder on the lines they have to use aluminum
2025-10-17 14:56:44
18
man.topper7
🪛Man Topper💡👷🏻‍♂️ :
Cos of illegal connection
2025-10-17 13:18:14
7
kojo3_0
Kojo💎😈 :
Just to make the work look neat
2025-10-17 12:12:49
3
kwadwonhice
Kwadwo Nhice❤️🥺 :
This new meter does not support copper that’s why we replace the coppper with aluminum…and moreover it’s not the contract who willingly does that it’s luttons instructions so please understand
2025-10-18 05:06:13
3
nanatibugravity57
Nana Tibu Gravity :
W)k) t)n adi sika no🤔
2025-11-02 03:47:32
1
laser4real
LASER :
And they don't do neat works too... The aluminum wire width is also thicker than the meter terminal holes that they'll end up cutting off the wire strands.
2025-10-30 22:27:20
1
user1322099385244
Ebedan :
The aluminum is for your own good because the meter terminals are made of aluminum so if the copper is use to connect in it, copper powder will be created which you will face problems in your house as time goes on So the aluminum is the best boss
2025-11-11 07:48:18
1
joyphil026
JOYPHIL ELECTRICALS :
It because most at times copper and aluminum join together it causes lose contact and it even catch fire
2025-10-18 06:00:37
1
nexphaseengineeringservi
Nexphase Engineering services :
its because the meter terminals are made of aluminium. so if copper is used for termination, it will one day lose contact
2025-10-18 05:49:28
1
ebene_zer4
Ebenezer :
dem go burn take go scale am.
2025-10-18 02:08:15
1
flamesdesparkles
Benjamin 🔥🔥🔥 :
look at all this
2026-01-07 13:42:31
0
kojorich2
richardannan312 :
bro they are going to sell the copper wai
2025-11-16 22:28:55
0
abdul.razak1052
zark nation :
tell them bro
2025-11-22 06:51:04
0
clintongyamfi148
DEDON MAN💼💼💼 :
oh say it again
2025-11-25 07:34:52
0
monilyflightingsystem
🔞MᏫ₦Î💎ⱠɎ₣💶ⱠI₲H₮I₦₲𝓢ψ𝓢₮Ꮛ𝕸 :
😢😢😢
2025-11-28 14:55:09
0
joyce.mills21
Joyce Mills :
I need a serious friend from Africa to work here
2025-12-26 03:18:30
0
strong.lion566
strong Lion 🦁🦁 :
🥰
2025-12-30 17:53:56
0
strong.lion566
strong Lion 🦁🦁 :
❤️
2025-12-30 17:53:57
0
7083thehimself
the man him self :
my brother asked them ooo hmmm because they want condem
2025-11-06 04:27:33
0
kemmusic626
KEMMusic :
For safe work ... joining copper and aluminum is not all that safe .. so aluminum from the meter to your MCB or RcD is safe
2025-10-19 08:56:03
0
karl.kingsford2
22K :
I don't understand why people choose to paint their house green, aaaah
2025-10-18 21:11:54
0
agy3babawu1
ING.SHEIKH DAUDA ISHMAIL🕌 :
But I have seen this things in Accra paaa why
2025-10-18 10:23:30
0
agy3babawu1
ING.SHEIKH DAUDA ISHMAIL🕌 :
It might be s3 u copper cable was too small that’s why they changed am
2025-10-18 10:23:05
0
ebenezerkwegyirarthur2
Ebenart :
they just want to steal ur copper.that is all.those cables don't go to ecg .is with the contractors and they sell them .
2025-10-18 09:17:25
0
doogoali
DOOGO ALI :
they sell it for scrubs
2025-10-18 07:48:44
0
emmaelectricalswork
BRAVE ELECTRICALS 0506830707 :
The terminal of the meter is aluminium and copper is very strong than the aluminium so they always do this to prevent loose contacts and the formation of carbon
2025-10-18 07:21:32
0