@plumbingdoctors: L2 on an Ideal Independent (same as Ideal Logic 🔧👂 I listened for the fan ✅ could smell gas 👃 but no spark sound ⚡— classic spark generator fault! Quick test with the multimeter confirmed it 🔋 swapped the spark gen and she fired right up 🔥 another one sorted 💪 #GasEngineer #BoilerRepair #IdealBoiler #HeatingEngineer #UKTradesman
I had an issue like that new electrodes and spark generator new harness on the flame sensor; it turned out to be the PCB.
2025-10-24 20:53:45
0
md :
very nice video brother
can you make some videos of how to use flue gas analyser.thanks .love your videos ♥
2025-10-24 03:13:34
2
Notification :
The accuspark is good for testing as well
2025-10-23 22:25:22
2
Far too tired :
Grab one of the little spark thingys - I cannot remember the name - very simple , don’t need to do this .
2025-10-24 10:12:36
0
Nil Stan :
Why would you unnecessarily remove the spark electrodes? which means now you have to change the gasket.
2025-10-24 09:24:28
1
bum_toffee :
How does that prove it’s not the electrode? I always test the cable from the gen to electrode also
2025-10-24 08:01:25
1
chopper1978 :
how much do you charge for them pal
2026-04-13 19:52:55
0
Imprettyhappytbh :
Sumps leaking as standard and starting to yellow the back of the pcb cover 😁
2025-10-24 19:25:35
1
Shae N :
Hello mate from Coventry myself, need to build my portfolio for my fast track course any recommendations on finding the right people?
2025-10-24 12:30:50
0
TheGasGeezer :
We always remove them when we grass em, handy to have a few in the van for temporary repairs until u can get back with a new one, like u say, very common!! Good vid..👍
2025-10-31 07:26:46