@brightpathelectricaltra: What is the problem in the distribution board #e#electricalw#wiringe#electricaltutoriale#electriciantipsh#howtowiree#energycommissiond#diyprojectsl#learnwithmeE#ElectricalWiringW#WiringTutorialM#MainSwitchL#LampConnectionE#ElectricianTipsE#EnergyCommissionD#DIYWiringG#GhanaElectricianE#ElectricalTrainingE#ElectricalWiring2#2GangSwitchW#WiringTutorialE#ElectricalTipsD#DIYWiringE#ElectricianTrainingW#WiringMistakesH#HowToWireL#LightingSetupE#ElectricalProjects
This happens if the insulation resistance of the cable is weak. and it's due to over heating or using the wrong cable size for installation.
2025-11-12 09:55:22
149
Sallieu Amara Kamara :
maybe the cable have carbon
2026-08-29 17:49:19
1
Makavelli 🤞 :
change the cable trust me
2025-11-11 20:47:22
5
Empress Yaa :
The insulation is weak so you have to change the cable and use the correct cable with good insulation.
2026-08-16 17:44:31
1
Ahianyo Kingdorler :
This happened when the cables bridge or neutral wire is not connected or curt
2026-08-01 02:52:10
2
ÑBÅ BRÛÑÖ :
Installation of Rcd is the best way to solve this problem
2026-08-01 02:58:39
1
Mhan lyk Kharling :
Earth linkage
2026-05-10 04:02:59
2
GYANGO ELECTRICALS/ WESA :
From my point of view: it must be insulation problem but I can also see a 4mm cable looping and its close to the tester.it might also be the cause from the 4mm cable looping. Don’t change the cable rather add RCD 4pole and change the incomer to 4 pole.
2025-11-12 01:11:30
10
"His comfort" :
the insulation resistance of the cable is weak
The cable rages use for the work is low, so due to that there will be over heating that's why the tester can detest current through the insulation
2025-12-04 16:29:45
6
Maxconelectrictech :
Earth leakage
2026-08-07 15:35:02
2
HOLLYLAND MEDIA :
Neutral break
2026-03-12 12:29:44
2
o o :
what do you think is the fault.first of almost atleast give us some explanation
2026-06-19 12:20:05
1
Nana Tibu Gravity :
So if you see this on a DB
You need to change all the wiring or where you see the power on the tester
2025-11-14 04:05:23
6
Edy billion :
remove the earth wire from the control and taste again
2025-11-13 23:23:00
5
papaju :
The insulation resistance of the cable is weak. This many be due to over heating of the cable
2025-11-12 08:19:18
5
ADX SOLUTIONS :
use the correction cable
2025-11-11 21:46:02
7
armah1234 :
RCD
2026-06-04 21:26:15
1
wilfred Armah :
Add RCD to detect were the leakage from
2026-06-04 11:36:32
2
👑OoBEY🫡 :
This happens if the insulation resistance of the cable is weak. and it's due to over heating or using the wrong cable size for installation.
2026-01-10 11:31:49
2
🥰360 🌎GUY ~GUY 😎4 REAL 🇬🇭 :
The is over the cable so you need correct cable for the installation
2026-06-15 03:52:01
1
Samson ovey :
earth furt
2026-07-04 12:07:42
1
fredy :
it's an open circuit. The neutral is not properly connected , resulting in a return current
2026-01-13 12:20:06
2
Nicholas :
short circuit
2026-03-12 18:56:01
1