jaybuhyra
Jay buhyra :
How did it pass inspection to start with?
2025-12-01 15:38:48
200
checkershand7
checkershand :
wait, is it okay to drill into structural steel? I thought you could only clamp.
2025-12-01 16:25:34
19
frank.sinclair61
Frank Sinclair :
Am I ever going to use this information...nope...am I watching all of this and taking mental notes...damn right!
2025-12-02 14:10:16
37
mattnelson_97
Matthew Benjamin Nel :
Shouldn’t building steel bonding wire go straight through transformer ground lug to XO unbroken?
2025-12-02 02:02:25
4
queeftenderloins
QUEEFTENDERLIONS :
Why the bonding connector for the building steel ground? I’ve always been ok running it through the grating in the bottom of the transformer to the bonding bridge without a connector.
2025-12-05 02:10:07
2
lampostsamurai
Eles :
grounding issues are always strange
2025-12-01 21:07:30
77
jim64
Jim :
Great work! When did anti seize start being necessary on copper?
2025-12-03 02:14:36
1
schmoppy
Scott Verkley :
In Canada we go continuously through the neutral lug then to case bond. Explained as you don’t want the neutral bond to ever get accidentally removed
2025-12-01 17:42:38
28
johnbe958
johnbe958 :
Did you ever replace the breaker for the generator?
2025-12-01 23:38:30
7
jwin45
jwin45 :
I have no idea what all this meant, but unsure did watch both videos....
2025-12-02 00:12:19
13
kwicker1990
kwicker1990 :
I get irrationally angry when I see slotted screws
2025-12-02 18:33:53
4
oumadman
OU MADMAN :
We used to have to cad weld all our grounds to the I-Beams from transformers
2026-01-20 01:22:24
1
splint_eastwood_1
Splint_Eastwood_187 :
Ehh that I beam was put there by a Civ E it's over engineered to begin with.
2025-12-01 22:30:10
19
ilikeicecream12684
Caleb Chandler :
I could listen to this guy all day
2025-12-01 22:05:06
16
black_of_cat
Black Cat6113 :
Two weird things. It was not grounded. And grounding it solved the problem.
2026-01-12 18:49:27
1
nrauls123
Nicholas Rauls :
Ray Charles did the inspection lol
2025-12-10 05:06:40
3
bpricazlqnb
Brian Price :
Worked with copper anti-seize when I worked at a steel mill. If it got on me, it was everywhere. Lol
2026-01-09 13:09:25
1
jeremybuckley80
Jeremy Buckley :
good job
2025-12-15 13:58:27
1
user712908004460
test1234567890 :
us wiring looks like something from 1600... damn...
2025-12-01 21:52:22
1
weakgod6
weakgod :
Noice!!!
2025-12-01 17:21:31
1
stevenwasikowski
Stefano :
nice!
2025-12-02 13:21:04
0
naldorvssian
Naldo Rvssian :
The transformer was produced a floating neutral
2025-12-02 13:16:57
0
ballstouching
100FATKIDS :
Sounds like the Vader guy 🤔
2025-12-12 06:46:00
0
alexdavis514
Pestilence476 :
Part two found me a couple scrolls down😂
2025-12-02 16:52:33
0
mrjefferson69420
Jeffery :
First
2025-12-01 15:34:31
0