@hausplans: We just installed a floor receptacle in front of large windows #build #howto #construction #DIY #contractor

Haus Plans ®️
Haus Plans ®️
Open In TikTok:
Region: US
Wednesday 03 December 2025 04:31:04 GMT
3576896
120711
553
581

Music

Download

Comments

urbexireland32
• Urbex • Ireland • :
Europe here! i’ve seen better and safer wiring in Senegal west africa!
2025-12-03 08:20:51
5282
danstreaky
Dan :
European wiring regs are beginning to slip in silly rules. But North America? Has nobody in 100 years thought..hmm that's a bad idea, we should change it 😂😂😂
2025-12-03 11:26:21
73
archibald.meatpants01
Archibald Meatpants :
nice dig at the electricians, also very accurate. 😂😂
2025-12-03 04:55:40
1437
matthias0049
Matze :
The wiring in the US is wild. we did it like this before WW2
2025-12-03 10:35:21
2516
cokefien3
cokefien :
What decade was this filmed in god damn, these types of connections are literally illegal in my country
2025-12-03 11:08:59
706
obeast52
JohnnyG :
your electrician looks to be wearing the same clothing as you
2025-12-03 16:08:19
1474
benwestlake
Ben Westlake 🇬🇧 :
American sockets / wiring is so bad!
2025-12-03 08:02:07
535
beluga9640
beluga :
the outlet wiring wouldnt pass an inspection in Germany!
2025-12-03 13:51:57
50
vongeis
VonGeis :
12’ between outlets on useable wall space. Just say you are installing a floor box, nothing code related.
2025-12-03 16:22:15
34
sparkyjoel72
sparkyjoel72 :
actually it's 12 feet in between outlets
2025-12-03 11:03:17
6
canadian_sparky0
canadian_sparky0 :
the vast majority of the time, walls with floor length windows are excluded from that code rule, as it's not considered USEABLE wall space.
2025-12-03 12:25:19
108
jacobmcguinness62
g'day :
American electrical work is so rough, it's like the stuff we remove from houses built in the 50s.
2025-12-03 15:34:24
21
yoshino_tan
Yoshino_tan :
. . . trust the splice not the device
2025-12-03 05:22:13
44
chriscm625
Chris M :
no pigtails to the device? trust the splice, not the device
2025-12-03 09:51:15
57
obnoxiouslizard
Brandon :
Why are we crimping grounds and not using pigtails. This is crazy work tbh
2025-12-03 18:01:19
0
shannonbonds
Shannon Bonds :
electrician..? crazy he has the exact same hands , hoodie, and shoes as you do.. lol.
2025-12-03 10:47:33
65
average_dadd
HeyHoDaddyOh :
No pigtails?
2025-12-03 04:44:37
27
lukesgoldies
The Goldfish Guy :
I love this guys videos
2025-12-03 12:39:47
11
kallen_olson
️Kallen :
Where is the new guy
2025-12-03 04:45:22
26
cjsirks
cjsirks :
Well, that was wired wrong illegally
2025-12-03 12:13:12
159
l.takala
Takala :
That cant be safe
2025-12-03 16:06:41
8
gapple_bees
Not Spiderman :
i hope that wasn’t the actual electrician doing those connections… understandable if it wasnt
2025-12-03 05:29:37
12
coffidelmar209
Hunter ⚾🦖 :
You can’t be more than six feet from an outlet? What does that mean in This context🤔
2025-12-03 17:19:19
71
mike264daoust
mikedaoust🇨🇦 :
The electrician and you wear the same clothes??
2025-12-03 11:56:35
8
pineapplemaster69420
pineapplemaster69420 :
you should have done decora outlets
2025-12-03 05:04:41
7
To see more videos from user @hausplans, please go to the Tikwm homepage.