@love2hvac: basic maintenance on a down flow (counterflow) category 1 80% furnace. This one was neglected and needed a good cleaning. before we start we give it a quick run to make sure it's operational. a wick check of inducer Amps compared to the data tag. make sure the flames look good, and then check the blower Amps after the inducer cycles off. just a quick run before it heats up. then it's time to clean. I start with the shop back and a paint brush and rags. then I disassemble the flue to access the blower. The furnace was installed behind a wall so the blower is not going to come out without a lot more disassembly so I clean it the best I can in place. I don't normally pull and clean the burners but since it was dirty and it was my first time here I did the extra step. this allows me to inspect the heat exchanger and the burner face. I pull and clean the flame sensor and note the hot surface if it is going bad. I inspect the inducer fan and the flue before putting everything back together. next video will be the documentation #love2hvac #furnace #hvac
Okay legit question: do you scope heat exchangers with an inspection camera? If so do you notice those models always have a crack right after the burner entry underneath the cell?
2025-12-05 04:13:40
5
DupeFN :
That heat exchanger is cracked u gotta look at it
2025-12-05 13:47:21
2
dmarsh_7 :
Man I feel so wrong questioning you, but why did you pull the manifold off to pull the burners?
2025-12-05 03:53:52
2
Tinman5000 :
My only complaint here is how much of the crimp is showing on the exhaust. Whoever installed that before could have done a little better! But it’ll work 😁
2025-12-05 19:17:17
1
#hvactechkid :
Master 🙏😎
2025-12-04 23:00:16
1
Blake :
Now that’s a maintenance
2025-12-05 23:55:31
2
RobTheRobot :
Zero grade steel wool is great for Flame sensors, thermocouples, thermopiles electrodes. Aluminum oxide emery cloth is also acceptable due to the absence of silica. I've used it many times with good results and strong signals on maintnenaces the following year.
2025-12-05 02:27:40
1
s1ickr1cky :
What filter system has no pressure drop?
2025-12-07 07:18:14
1
Juan J. Gonzales :
Good job cleaning that furnace 👍
2025-12-04 23:46:44
2
Blake Edwards1181 :
Chefs kiss
2025-12-05 02:44:34
1
Randy Smith :
One thing I hate is pulling the blower on a down flow, at least it was an 80% so you didn’t have to jack with glue or cleaner 🤙
2025-12-05 00:43:38
2
KasualKid :
All that to not check the cracked heat exchanger 🤦🏽♂️
2025-12-06 11:35:14
1
itsthathvacmac :
GLOVESSSS!!!! 😂😂😂😂🫣🫣🫣
2025-12-04 22:35:29
1
Native Yazzie :
👍👍👍
2025-12-30 11:26:40
1
HVAC_TIPS :
use this button to support hvac technicians
2025-12-04 22:02:02
3
Next Level Tek :
Yep. The Ole " it was working before you got here " . Seen that scam pulled on me before
2025-12-06 00:57:53
2
bowhunt304 :
A dollar bill works really well for cleaning your flame rods .
2025-12-07 12:57:52
0
Chingon :
Thought for flame sensor you you a benji 👀
2025-12-06 07:12:19
0