@plumbingdoctors: Baxi 800 system boiler 🔥 paired with a Tempest 300L unvented cylinder 💧 But here’s the clever bit 👇 We added an underfloor-style heating manifold to control every radiator individually in this 7 bed HMO 🏠 Each room = its own thermostat 🌡️ Tenants just press BOOST ▶️ Heat on. Walk away. Simple. Landlord control? 📱 ✔️ Set max & min temps ✔️ Boost limits ✔️ Schedules ✔️ See heat usage per room ✔️ See who’s using the most heat System used 👉 Inspire Home Automation Highly adaptable 🔧 Highly customisable ⚙️ Very cost efficient 💷 We also fitted a bronze pump on the unvented cylinder 🚿 ➡️ Faster hot water draw-off ➡️ Near-instant hot water ➡️ No more running taps & wasting water Want more info on setups like this? 👇 Drop a comment #HMO #SmartHeating #UnventedCylinder #HeatingEngineer #Landlord
Nice setup. How are tenants billed? If one room is set at a high temp and another cooler, is the cost split equally?
2025-12-16 12:06:09
4
My Castle :
trying to understand why pump is not needed considering it's 7 bed. Is it because it's installed in the loft? and it's flowing down so not much stress on the boiler pump? usually the boiler pumps are quite weak
2025-12-16 12:31:11
0
dopey :
Too much to go wrong. Technology has gone nuts
2025-12-17 22:58:30
3
A :
Will they teach me this on the 5 day plumbing course
2025-12-16 05:36:13
0
01126342t :
i have this set up in my home but with the actuators on the radiators. saves a fortune in heating
2026-01-04 13:43:28
0
temu.google :
I wonder what will happen if heat demand is made on all roads at one time . The system will work to bring one rad to temperature first
2025-12-16 11:42:35
0
Muhammad :
Only a suggestion.Could Honeywell Evohome done the job cutting the cost of the manifold and all the rest of it.
2025-12-18 09:03:07
1
KevinTony1611 :
Looks like a great idea with the manifold. Dose the manifold have 15mm connections on it ?
2025-12-16 21:38:55
0
Safe home heating :
Nice job
2025-12-16 07:55:24
0
Nugget :
Not sure of any flooring that will take the same temperature that is required by the hot water cylinder, you’re going to be pushing 65 through the flooring in a bedroom? Madness.
2025-12-17 23:11:08
0
Mck888 :
Are the pipe to the rads 15mm? If so how do they connect to the 16mm UFH manifold?
2025-12-16 16:28:33
1
Shahid Khan :
That’s brilliant work
2025-12-15 23:09:38
4
Quasim Ali :
whats the cost for a 7 bed hmo?
2025-12-16 07:16:13
1
PRIME Heating & Plumbing :
Mashallah brother is on it.
2025-12-18 10:27:03
0
Amazon expansion :
Amazing work
2025-12-17 13:37:45
0
Riz plumbing and heating ltd :
Awesome set-up 🥰
2025-12-15 23:06:59
1
derbyshire121 :
yes good job
2025-12-15 23:19:16
0
mochadwick7 :
hie much all this cost
2026-02-10 23:05:10
0
bash Malik :
What kw is the boiler
2026-01-01 01:02:51
0
Bill_Bains_01 :
How much
2026-01-18 12:01:40
0
Abdul Tohid :
amazing love this 👏
2025-12-16 23:08:13
0
Crusader25 :
MashAllah
2025-12-16 20:24:17
0
markeb :
so what size pipework is it on the manifold. also what is the maximum length of pipework you can use for each rad before having to increase pipe size. thanks
2025-12-16 18:38:59
0
3gaza :
Solid setup
2025-12-16 06:41:11
0