@winnidesigns: Basement Bathroom Plumbing @Kenco helping us out!

Misha Panchishak
Misha Panchishak
Open In TikTok:
Region: US
Wednesday 14 January 2026 13:10:44 GMT
1014280
21085
249
834

Music

Download

Comments

jc_spence22
jc spence :
NO BEDDING IS CRIMINAL
2026-01-15 03:23:04
120
nateapowell
NateSD :
Wet vent has to be 1 size larger than drain per UPC. That should be 3”
2026-01-14 23:04:06
6
tiagoalbuquerque05
TIAGO 🇺🇸x🇧🇷 :
I have a question, it might be silly, but can these pipes be used for drainage?
2026-01-15 23:46:25
3
dylansparks6
Dylan Sparks :
That’s how you prime. Jesus anyone is a plumber I guess
2026-01-14 22:17:25
64
smallohiofarm
Down on the Farm :
Absolutely not. Saniflow system would have saved the customer thousands.
2026-01-14 21:33:16
34
landrywilson70
landry wilson :
Omg that would not past in ca !!!!
2026-01-16 02:59:32
2
marioarmas01
Mario Armas613 :
Awsome skill level, heck you explained it perfectly. Thank you.
2026-01-14 17:07:45
66
olstinky42069
Stinkysteve418 :
No gravel in the hole?
2026-01-15 00:14:18
12
elmacjrlxwq
Jireh plumbing llc :
You can’t use bushing in horizontal in Colorado just vertical
2026-02-04 06:47:40
2
dpe690
DPE :
almost the way we did the same thing in phila except the vent has to stay full size
2026-02-05 21:52:55
2
viva_la_koko
Viva_La_Koko :
3” underground?
2026-01-14 20:07:48
11
nathanhuff315
Nathan Huff :
Why this instead of a macerating toilet?
2026-01-14 15:46:05
9
jimclemente838
Jim Clemente838 :
I don’t know the first thing about plumbing, but I can tell you this that job will never be replaced by AI.
2026-01-15 12:15:07
1
paulboyd379
Paul Boyd :
No plumbing inspection before the back fill?
2026-01-14 15:10:20
6
johnhelldiverfi
John Helldiver :
How does that violet stuff work, does it expand?
2026-01-14 13:23:53
7
massplumber81
Matt Fox :
that would fail here in Massachusetts..no flat vents
2026-01-15 03:26:18
19
flamingtoaster69
FlamingToaster 69 :
That would fail on NC 🤙
2026-01-14 17:15:46
13
sipis1013
JM Ramirez Romo :
No inspection?
2026-02-18 14:37:32
2
kylebousquet687
kylebousquet687 :
if this is NH, cant use flat vents...
2026-01-15 00:30:51
6
stevmendoza
Stev Mendoza :
everything good, but why regular 90 and not long ones?
2026-01-14 16:25:37
6
thatsayejay
ThatsAYEJAY :
What state are you in bc in Texas you cannot put foam core (cellular core) under slab must be schedule 40 . You used schedule 40 with the 2in just not the 3in
2026-01-15 04:44:18
4
roro124582
user8446309336046 :
Good job parther I’m in California upc code but this is diferent is ipc code clean job 👍
2026-01-16 19:49:03
2
edscdoris
edscdoris :
great video
2026-01-16 09:39:36
1
mmastermi
mmastermi :
No sand ? No inspection
2026-01-16 20:39:50
1
127.0.0.1_lo1
Mr. Loopback :
Didn’t even get enough glue and primer far enough in the connecttion.
2026-01-14 19:26:39
4
To see more videos from user @winnidesigns, please go to the Tikwm homepage.