@catscanguru: CT Protocol of the Week | IV access in CT, what we can and cannot use for contrast injection. #cttech #ctscan #radiology #radtech #radtechstudent
anyone doing IV access should really be shown how bad contrast infiltration can be
2026-01-17 01:04:41
45
Johnny Medina :
When I was a baby tech I was seconds away from using a Cordis for an angio. I finally turned around and told the nurse I gotta be honest, I’m not comfortable doing this. That line says nothing about pressure rating on it. He made a call and said don’t use it. Glad I trusted my gut!
2026-01-17 01:21:14
7
Carol A. 🎶🌻 🐾 :
I love when I get a 24G in the thumb 😫
2026-01-17 11:14:01
4
Amandy :
So many variables, but don't come at me with an IV hanging half way out or a 22 in the hand and ask me to just try it, because it flushed well with a hand push. That IV won't hold up with contrast injected at 4cc/sec or higher. Trust your CT technologist's judgements.
2026-01-20 00:22:29
0
Cherillynn :
and nooooo- I am not injecting into your 35 psi rated IV tubing… saline lock it or start me a new line… to the bottom of my CT list they go…
2026-01-17 02:57:36
6
Harley D :
Idk if you mentioned this in your previous videos but people NEED to know the difference between an infiltration and an extravasation. An ED nurse looked me in the face and told me there was no difference between a saline infiltration and a contrast extravasation. There is a difference and thought compartment syndrome is rare, an extravasation needs extra precautions
2026-01-18 05:06:05
1
Nour Nofal :
What is an appropriate reason to do a sinus with contrast exam?
2026-01-16 07:09:47
0
kdoc1978 :
Not normally I would agree about the 22 gauge IV, but if they are a really hard stick and they are super tiny and small, you can use a 22 gauge at 3 1/2 cc second. As long as it flushed as well by the way.
2026-01-16 10:25:34
0
kerrilynn23452 :
We (pediatric hospital) recently changed from using diffusics to B Braun - we can power inject a 24G CTA 22G and larger.
2026-01-21 08:07:17
1
GHULAM YASEEN :
Why use a contrast media in CT Scan ??
2026-03-03 10:55:21
0
juanespinoza :
Thank you for the information.
2026-01-16 14:17:30
2
SeeThruU2014 :
I like to tell the nurses, that our contrast is about as thick as d50. would you inject d50 at 4ml per second into that IV? at one point in time one of our nurses felt the contrast, she said it's about the same as the d50. That's where I got that association.
2026-01-16 13:02:13
9
Christopher Bell :
It’s crazy because I just had an issue related to this yesterday. Pe study and they wanted to use a hand iv. 3 ivs later and we were able to do the scan
2026-01-16 18:42:20
0
Demeary Britt :
I've never seen ivs like that before!
2026-01-18 15:06:03
2
Guy Luongo :
Great Job!! You explained it very well!!
Injectors will sense the back pressure of a small gauge catheter and my shut down mid injection. That is a safety feature within the injector. Not to be confused with something wrong with the injector itself go back in the history and see whether the injector overpressured.
2026-02-12 20:00:19
0
Trish Adams Portier :
22g and 24g diffusics allll day. 20g for cardiac studies.
2026-01-18 06:32:00
0
Godsrebel :
YIKES!!!!
2026-01-16 04:35:26
1
GHULAM YASEEN :
Explain contrast complications
2026-03-03 10:55:51
0
Reyan :
how to calculate contrast volume for pt
2026-01-28 13:25:33
0
Jackie Tots :
Got a 24 in a foot the other day, laughed so hard🙄😳
2026-01-17 18:08:59
0
Joey Nobody, R.T.(CT)(R) :
first time ever we blew an emt 20g in one ac, a nurse 20g in the other, both only at 3L/s, and ended up using a femoral access for my first time ever. crazy night but they made it in the end
2026-04-08 12:24:53
0
Casey Fetters R.T.(R)(CT) :
@nurse @NursesOfTikTok
2026-01-17 15:39:36
0
To see more videos from user @catscanguru, please go to the Tikwm