@in.power.electric: ⚡️code section 352.44 Expansion fittings!! Make sure you're using the Table 352.44 a for any PVC runs that are exposed to the elements, and there is a temperature variance! #NEC #electrician #sparky #sparkylife #electriciansoftiktok @Milwaukee Tool @Mike Holt Enterprises @electricaltime.com @Stevenj120volts @Tanner The Electrician @The Angry Sparky @Nic.Electric @Shameless Plug Electric @SurgeElectricalTraining @Mape Electric
By code, you don’t need one if it’s in the same structure. Only between two separate structures or structure and ground. That house is not expanding if it is a against the foundation is cracking lol
2026-01-23 02:30:51
9
DustyyR6 :
this video isnt stopping pvc from getting hot and warping. its just allowing correct expansion when it does that. its still going to look like a dump in 3 years regardless
2026-03-19 04:58:09
1
Okiesparky85 :
the picture looks like flex
2026-01-26 18:32:17
3
Shi Tido :
Or… schedule 80….
2026-01-28 15:38:06
1
chungus213 :
Another option is use something that doesn’t melt when the sun beats on it, metal conduit instead of cheap plastic garbage?
2026-01-31 17:47:54
1
user6030863679109 :
Would look ALOT better if the tik tok electricians would use EMT. PVC should not be seen ever.
2026-01-24 12:40:38
5
Billy :
conduit emt galvanized bro with metal lbs why u using that shit
2026-01-23 14:31:32
4
walterkarrick :
Its called more straps
2026-01-29 07:49:47
1
MaD MaC :
hello plastic melts
2026-01-23 12:46:26
1
Superd67 :
2" $35 bucks 😳
2026-01-23 15:33:38
1
Sparky :
Make sure you’re installing expansion fittings accordingly!!👍👍👍
2026-01-23 01:01:53
4
Dirt S :
Just use schedule 80 instead of 40 it won’t happen and you don’t need an expansion fitting on the same structure
2026-01-23 15:29:45
2
shocker4807 :
🤔 Nope
2026-01-23 12:46:31
1
Gilles🇨🇦✖️ :
Pvc doesnt last as long as before in the sun it will become britle and i would put a extreme amount of straps
2026-01-27 18:30:04
1
Fourth212 :
Wrong wire cute tho , and that PVC will also sag 😉
2026-01-23 21:39:26
1
BITMO :
that didnt happen because of thermal change. look at where those straps are installed.......
2026-01-23 17:20:58
1
eco214tango :
YESSSSSSSS!!!
2026-02-13 15:19:05
1
juliogarrido208 :
EMT, rigid…? just need a conduit bender and basic electrician skills.
2026-01-23 18:26:23
1
sparkyjoel72 :
the barrel of the expansion needs to be supported, and according to the manufacturer those click straps don't allow the conduit to slide.
2026-01-23 11:14:58
1
SJ :
can also u expansion joint. you guys call it pipe install like pipe.
2026-01-23 02:19:03
1
She’s full of D’s :
Yea but that first pipe was just simply installed to look like tihs, the clips are a siding layer below
2026-01-23 02:29:18
1
Barron :
use emt
2026-01-26 21:05:18
0
William Cummins :
Just run emt and bend it when need be lol
2026-01-24 05:35:44
1
Angry_Ginger :
well considering thats liquid tight in the first pic
2026-03-04 21:55:04
1