@winnidesigns: Fixing a Plumbing Mistake!

Misha Panchishak
Misha Panchishak
Open In TikTok:
Region: US
Friday 30 January 2026 14:16:26 GMT
236786
6790
247
374

Music

Download

Comments

asvelezserrano
A Velez Serrano :
First mistake was used plex 🤷🏽
2026-01-30 16:58:55
65
strollo523
Scott :
25 yrs in the plumbing biz. We always used brass nipples for our tub spouts. Better flow
2026-01-30 15:13:14
38
novicanezero
NovicaneZero :
Always trust a man that shows his mistakes and how to fix them.
2026-01-30 14:54:49
513
masterwalker19
Master Walker :
What about the inlet ports. They're smaller than the pex.
2026-02-03 01:06:29
3
jasonkanupp
Jason Kanupp :
Exactly water stacking
2026-01-31 15:43:44
3
stealurkill_phd
StealUrKill :
damn that's why mine does that lol
2026-01-31 03:35:22
3
uumom173_sue
Uumom173_Sue :
Well done. Someone pointed out a mistake/better way, and you fixed it.
2026-01-30 19:07:18
50
paulboyd379
Paul Boyd :
Dude, are you in the western New York area? Are you just the bills fan?
2026-01-30 16:40:50
2
shongum_cowboy
Shongum Cowboy :
Go Bills!!🦬🦬
2026-03-18 23:15:10
2
bigb6677
bigb6677 :
I use 3/4” pex for tub spout (1/2” NPT to 3/4”pex on both ends… also solve the problem without $2K tool
2026-02-01 03:39:14
3
samuelatkinson61
samuelatkinson61 :
Correct must be copper or cpvc piping for tub spout. I too learned this the hard way. But to be fair. Most Manuals specify this in the fine print.
2026-01-30 22:03:52
3
gonz.0o0
ChaChaChaChia :
Keep up the good work! Way to own up to it 👍🏼👍🏼👍🏼
2026-02-03 15:14:01
1
chuck6148
❌️ Chuck ❌️ :
READ THE DIRECTIONS
2026-01-31 01:16:24
6
phoenixremodels
William Paguaga :
Thames fact that he realized and replaced it. 🔥🔥🔥🔥🔥 Respect brother
2026-02-01 04:47:31
1
pureblood_plumber
Pureblood_plumber :
This infact is true I’ve had to fix many of these
2026-02-10 03:40:59
1
adenlarson429
Aden Larson429 :
Thank you!
2026-02-08 21:32:04
1
bigdaddy2689
Contractor :
We do whole homes in 3/4
2026-02-02 21:58:36
1
bradfluker
Brad Fluker :
Go Bills!
2026-01-31 17:09:22
3
davidclemmonsin
❌ David Clemmons Indiana Gen ❌ :
Change to 3/4
2026-01-31 01:03:05
4
hiphopanomymous
hiphopanomymous :
TheInstructions for tub spouts / valves specifically state it has to be copper in the spout feed in all I’ve seen.
2026-01-31 17:34:15
1
chacekelley0
Papaws cateye :
Tub spout has to be ran in hard pipe either copper or brass or galvy if you want but yes i.d. Of the pipe is what causes that problem
2026-02-01 14:05:22
1
gy6bro
gy6bro :
Copper pipe with press fittings is the goat way to do plumbing. Can’t beat it
2026-01-31 22:34:40
1
danieltoben
DanielToben :
Good to know
2026-02-01 18:12:42
1
master.of.none.619
MasterOfNone :
It’s a volume thing. I was raised by the best plumber I’ve ever met… at the valve we always do copper. No threading on either.
2026-02-02 04:40:42
1
jgolfin77
JB :
It’s fine with expansion fittings. With crimp no bueno.
2026-02-02 02:32:45
1