@civilengineeringhub001: Old building doesn’t always mean demolish. Sometimes… it means retrofit. Retrofitting is strengthening an existing structure instead of starting from scratch. And one powerful method? Column jacketing — giving weak columns a structural upgrade to carry more load safely. More strength. Better performance. Longer lifespan. Smart engineers don’t just build new structures. They know how to improve existing ones. Would you demolish… or strengthen? dro your thoughts in the comment section👇 #civilenegineeringhub001 #civilengineering #civilengineeringstudent #retrofit #constructiontips
so what happens to the foundation that is designed to carry the previous structure. i understand we can do jacketting to columns and beams
2026-02-15 19:56:22
35
GÎTONGA💵💷💰🇰🇪 :
is underpinning an example of a retrofitting
2026-02-15 18:53:03
15
GOOD SHEPHERD TEENS CLASS :
What is the difference between retroffing and underpinning
2026-02-16 16:19:30
6
marcs :
perfectly said but they are not added for more loads or floors no they are added for strength failure adding for more floors is not allowed because you will have to start from the foundation except with under pinning
2026-02-18 06:49:57
1
Fenilo :
this is such a nice content when it comes to our profession mamaa 🥰
keep it up💯
2026-02-15 22:36:26
10
Daniel Quartey :
in such situation a structural integrity testing must be made first
2026-02-19 12:50:18
1
Engineer Nsubuga mj256 :
thnxx for teaching
2026-05-07 21:19:14
0
tumainikakore👈 :
well understood Engineer
2026-02-17 07:03:58
1
Crystal Interiors :
Retrofitting is mostly used where Design Failed
Structural Failure
2026-02-16 06:18:46
2
ALEX KIOKO :
underpinning
2026-02-16 19:50:27
0
PACEMARKGROUPLTD :
for us here, we know that madness, a two floor building we design 4floors foundation, clients are mad, when they get money increment
2026-02-17 04:43:38
2
FOUR BROTHERS INTERIORS & DECO :
is it only for exposed columns and beam?
2026-02-16 04:09:39
3
Analtical Hess :
Perfect explanation 😁
2026-02-16 08:15:04
1
Eng. kamau wamui :
very nice I like your presentation for an easier understanding
2026-02-16 14:03:05
2
gilesxahen :
can't find the link
2026-03-10 05:56:46
1
Lastone :
what if you re enforce the collom and the weak when it can't distribute the load entirely
2026-03-24 12:16:11
1
Muru Wa Njanja :
Inter
2026-02-15 22:18:12
1
Kayiira Godfrey :
woowa
2026-03-26 05:31:34
1
Kyeriku Gideon Manua :
Actually, a structural failure gives warning for occupants to escape or evacuate before collapse.
2026-02-17 08:07:55
1
solomonwisdom522 :
How best will you cast a jacketed column then
2026-02-16 11:53:12
1
Joel muiruri :
for me I could make a decision of whether to build after a clean analysis of foundation and sail barring capacity and all structural elements, and perform UPV to the existing columns.
2026-02-16 02:14:48
3
Xplicit247 :
this will actually affect the foundation of the building. adding superimposed loads on the structure without considering the integrity of the structural foundation, will have a general effect on the building.
2026-02-16 11:19:22
2
Mwangi wa G :
There' is an abandoned building at Junction next to Total Eneries with footprints of coop bank. Can column jacketing revive the building?
2026-02-17 00:35:36
1
Blair Janam :
Alaa, there's also retrofitting in Refrigeration and Air Conditioning, which basically means modifying an existing system, e.g., changing to the latest refrigerant (which comes with changing a few accessories as well).
2026-02-15 20:17:33
3
lumijonathan3 :
I think is better you analyze the problem, compare the cost and time it'll take to complete. Also the expertise of your workforce
2026-02-16 07:10:04
1
To see more videos from user @civilengineeringhub001, please go to the Tikwm