@hvacsavier: When the thermostat won’t cooperate… go straight to the source. 🔧 Bypassed the Honeywell stat by jumping R to Y,G and W at the base to call cooling and verify system operation. Quick way to separate stat vs. equipment issues.
Can you help me with my wiring I can’t get my ac unit to kick on
2026-08-30 03:04:49
0
consciousness :
put it on c to check the fuses
2026-02-20 21:33:20
169
HVAC Tech 1 :
Make sure you test the common to make sure it’s still good
2026-02-20 03:32:37
72
Ape man :
Bro idk why I never thought of doing it that way
2026-02-19 23:47:57
170
Dequan Davis :
I replaced my thermostat and it worked for a day. the thermostat calls for cool but it stopped sending the signal. but if bridge red and yellow it turns on the out door unit. but won't do it while hooked to the new thermostat.
2026-04-29 20:24:42
2
Joey :
Not hating at all serious question, if you do that won’t it not turn on the fan? Just the outdoor unit?
2026-02-20 02:14:14
0
Tim :
Or use the thermostat's test mode
2026-02-20 19:31:45
7
Deonte :
These thermostats you use E and w2 for heatpump applications, it specifically says do not use W for it (if it’s a Honeywell pro series TH14blahblah) so this would be on a furnace guys. Even if it wasn’t I don’t think it’s that deep. Assuming it is a heat pump/electric in this scenario looks to be jumping to conclusions imo.
2026-02-20 13:03:36
0
Pope Swamp the Mad Queer :
It’s a shame you just told people to run electric heat without a fan…. Thank you for the service call and the opportunity to have a laugh at a home owners expense
2026-02-20 11:35:10
2
tim :
why not just do it at the air handler? I mean the wiring is already accessible and you don't leave smudged fingerprints all over the customers wall and thermostat... plus you will most likely end up in there anyway
2026-02-21 05:30:14
0
joeoquendo361 :
But why would you jump out y like that, you’d have no blower motor
2026-02-20 15:01:20
0
Trey🦆 :
I been in the field 4 years did not know
2026-02-20 00:06:06
15
fragout1599 :
The heater will be just the heating elements?
2026-02-20 01:45:08
0
OakeyDoke :
or you can do it all at the AH/Furnace so you can actually see what's happening
2026-02-20 01:47:05
1
17 :
HOTTT DAMNNNNN🤯🤯🤯🤯
2026-02-20 00:35:14
10
g :
2026-02-20 00:35:21
4
They not like Uce :
me over here with all my jumpers 😂
2026-02-20 04:29:39
3
Fernando Rodriguez III :
Just do it at the board
2026-02-20 00:11:24
3
rj_datek :
Brooooo this is dope
2026-02-20 00:02:42
4
the_dude7978 :
you mean to tell me that for 40 years...ain't no way
2026-02-20 14:39:35
1
Bryan Z :
Just learned something 🔥
2026-02-19 23:53:21
3
YeetMyTicTac :
if you do it at the unit, you can tell if its a thermostat or unit issue.
2026-02-21 09:48:09
3
To see more videos from user @hvacsavier, please go to the Tikwm