looks wavy because the framers didnt mark their crowns.
2026-02-22 03:01:44
19
Bull121975 :
I’ve always caulked my hardy board after installing before painting
2026-02-21 23:01:27
12
❌️Endless empire creations❌️ :
most of that wave is the wall framing
2026-02-22 20:17:51
9
David :
Under manufacture specs, there is supposed to be a 1/8 gap
2026-02-22 02:51:18
3
tb :
dap😂 I challenge you go to any new houses being built look down the side at the walls it will blow your mind. I refuse to paint them because I know I will not get paid when the inspection comes
2026-02-22 00:15:13
0
Mike K :
You put flashing behind the seams and no caulking.
2026-02-22 14:47:36
11
A.T.2 :
Unless you frame exterior walls with LSL’s you’re going to get waves on a wall that size. No caulk on joints, just flash them
2026-02-23 03:05:46
0
joe :
nailing in the plywood does that. studs only
2026-02-21 17:57:35
1
keitheldred17751 :
I prefer to use hat channel ferred to straight and then attach with clips! Perfect can happen!
2026-02-21 18:05:36
1
Johnnywad :
I agree 💯. ppl need to start listening
2026-02-22 00:39:37
1
Dick L :
Don’t use clap boards, always a problem with noise and waves , if you caulk or nail at all at the bottom, warranty voided
2026-02-21 23:25:15
1
mudzillo :
expands and contracts too much, especially with darker colors
2026-02-22 03:06:35
1
Craig21 :
gotta breathe
2026-02-21 17:48:00
0
Jimmy :
Obviously whoever installed the siding didn't know what they were doing....
2026-02-22 19:44:05
0
VooDoo750 :
it's the framing bub
2026-02-21 20:35:09
3
Corncob8621 :
Slip sheets and factory joints in the field only
2026-02-21 20:34:53
1
★ Chriz Dior ★ :
Put the fries in the bag bro!
2026-02-22 03:36:43
0
Randy Gaspard :
to clarify for everyone once upon a time, JH recommended everything be caulked - I’m assuming they had some failures of some issues and then later changed their directions - all but joints are supposed to be flashed & left open
2026-02-22 02:12:01
2
Ryan Kelley :
Hardie lays flat against the wall. You can’t float it.
2026-02-22 16:27:14
0
phillydog60 :
because yr supposed hang siding not nail it home
2026-02-22 17:42:23
0
Turo :
Gotta use Osb instead of tply behind the siding
2026-02-24 05:48:52
0
TUBDaDDy! :
1/8th inch gap. no vertical gap caulking. only caulk where it meet window trim or siding trim no vertical and nothing underneath or above
2026-02-23 04:46:11
0
Ë :
Um, depending when it was installed… the hell you don’t
2026-02-23 03:00:13
0
Mark S :
Exactly why I hate Hardi Board.
2026-02-23 16:51:00
0
Michael Rodgers713 :
flashing behind all joint only and only factory to factory. I see so many guys cut in the middle of the wall. hacks. should caulk under each end at trim then set siding into caulking and then caulk front only at trim
2026-02-22 01:52:43
0
To see more videos from user @builtbyblake5, please go to the Tikwm