In all my years, today is the first time I’ve seen one of those. I’m stoked to learn new stuff!
2026-02-24 04:44:35
137
Yuji V :
If you need a little more space, 2 chase nipples and one ridgid coupling works great
2026-02-24 19:12:31
14
5.11.75 :
Close nipples use FOUR locknuts, not two, actual rigid locknuts won’t thread close enough to the center to reach the boxes. With four locknuts, the covers don’t touch
2026-02-25 01:17:40
25
user5732412561084 :
I usually just put 2 box connectors and a small piece of EMT in between
2026-02-25 11:50:43
3
❌Gnoswal❌ :
Bang ring? That's a new one for me.
2026-02-24 15:20:31
15
QuintillionWaystoDie :
"never do in half what you could do in three quarter"... fast forward to my conversation with my boss/owner today, me: "If youre wanting to run a 3" under the floor before we pour cement lets run two 2" below it. three phase in the 3" and One 2" for single phase, the other is just for future use." him: why would we need to do all that just run everything in the 3"...." my good sir, conduit fill limits exist and i have zero interest in pulling air line through the same conduit as power nor do i want to have to pull it all back out to repair an air leak.
2026-02-25 23:48:14
3
DAB H&C :
😂 This f thing
2026-04-09 23:11:53
1
Logic Electric :
Back to back emt connectors or a 2” by 1/2 or 3/4 nipple. No one in the trade would ever use a close or chase nipple. I think one of the supply houses carries that 3rd option in Arlington. Love your content,
2026-02-26 03:01:15
1
Jfill28 :
electrician of 20 year here, never seen the 3rd 😳
2026-02-25 00:05:15
2
Squatchy :
I've never seen those before, learn something everyday
2026-02-25 23:56:05
2
Skylar Gartamaker :
It takes 4 lock rings, but you can get box separation with a close nipple and lock ring on the inside and the outside of either box as spacers. Not ideal though
2026-02-24 23:10:13
1
Bensclassicstuff :
Dang I miss these videos….. I was getting like 10 a day then they all disappeared for a few weeks until this one
2026-02-24 04:40:02
1
user4151381588448 :
double locknuts
2026-02-24 21:19:52
4
The Poot :
ran into this issue twice recently
2026-02-27 09:48:44
1
H-DEZ :
Lol looks like a coupling with lock nuts
2026-02-24 23:37:25
1
💭 :
why are 4x4s so damn sharp in the us
2026-03-21 09:55:50
2
Johnny Kratsas :
I have seen a new product, where it's a expandable box. you can start with a 4sq and remove one wall to add on a single gang, or 2gang. the beauty is you can keep adding based on need.
2026-02-24 13:50:37
4
Too Two :
How am I the first like and second comment on this? Mr. Boden is legit the electron gangster!
2026-02-24 04:05:13
3
legokevo2111 :
CoOL (but seriously this is cool)
2026-02-24 04:02:35
8
matt :
The language at the end offended me 😂
2026-02-24 04:32:11
6
joshypooh001 :
Or just get single gangable boxes the are made to go together and you get more box fill
2026-02-24 16:54:07
1
david a ruffing :
or buy a 4"X 8". aka a 4 device box
2026-04-25 12:28:46
0
TheSparkyFox :
The way you describe everything 👌🤣
2026-04-14 12:12:37
0
Magwagon08 :
Ok two videos down and I’m subscribed 😂
2026-04-15 11:02:28
0
big sparky :
20 years in the trade, I had no idea those existed...