@letsbetechs: Love coming across abnormal issues! Sad this wasn't on my firsthand list. Thanks Jacob Stanley for sharing this with all of us, hopefully we can get some of our brightest on the case and get some answers here! #hvac #hvactechnician #hvaclife #refrigerationtech #hvacdiagnostics

Lets Be Techs
Lets Be Techs
Open In TikTok:
Region: US
Sunday 01 March 2026 01:29:29 GMT
24107
1399
67
86

Music

Download

Comments

dhibbert78
Dhibbert :
I’ve seen a bad compressor cause condenser fan motor run continuously.
2026-03-01 02:07:00
32
rockylozano1
Rocky Lozano :
Yes have seen it before on Trane and American standard units the fixe is to change the contactor to a two pole contactor. I’ll try to find the memo as it was about 10 years ago.
2026-04-05 04:51:54
7
silverwolf1199
silverwolf1199 :
permanent magnet compressor motor turning into a generator when it runs backwards?
2026-03-01 01:46:53
5
thathvacguy1989
Patrick Allen :
I would start with capacitor and installing a 2 pole contactor if it has a single pole currently
2026-03-01 04:21:19
6
hvacwithme123
HVAC With Me :
I was initially thinking something to do with the capacitor discharging after voltage has been removed. That would explain the 400v at the contactor on the compressor side since one wire typically does run to the cap from one of the terminals on that side of the contactor. I would throw a fresh cap on it and see if it continues to do it. If it continues to happen, run through the wiring on the schematic and verify it is properly wired. Something is feeding when it shouldnt.
2026-03-01 04:55:50
2
danielheady87
Daniel Heady :
Seen this in 3 goodman units and couple other brands it’s a short in the compressor causing a bleed back of voltage through one leg. Unhook the compressor from the equation and it won’t backfeed voltage anymore then you will confirm internal compressor short. It can run like that for years or fail tomorrow
2026-03-01 18:19:15
8
jordanpatt2848
Jpatterson :
Fan capacitor wires are wired to contactor
2026-03-01 04:28:48
15
tonyloyd4
Tony Loyd :
Usually if fan runs when contactor not pulled in and single pole contactor. I found grounded compressor
2026-03-15 01:56:29
3
johnpone4
Johnnydonuts :
You could have a shorted or CHAD line voltage wire as well
2026-03-05 15:28:14
3
charles.robinson722
Charles Robinson :
They went to the one pole contractor on heat pumps the same time they did away with the accumulator. It’s for a small internal oil heater.
2026-03-24 22:52:23
3
hvactechlife
Michael Wiseman837 :
mabey the fan not speeding up at all.
2026-03-01 15:47:25
3
hvacrverse
HVACRverse :
it happens put a two pole in and have one side of the fan motor on the line side so it doesn't get fed the back EMF from the compressor
2026-03-01 03:05:49
8
djmhjt2ia
djmhjt2ia :
Since the compreessor was running it has a magnetic field. After the disconnect the coolant spun the compressor, turning it into an alternator with the fan as a load. The compressor probably generated a higher frequency than 60Hz, causing the fan to spin faster than normal.
2026-04-14 22:17:19
4
small.acorn
small acorn :
At that voltage I would suspect the capacitor is bleeding off charge as it shuts off
2026-04-18 01:30:27
3
hvac_al_ms
HVAC_AL_MS :
scroll can cause back end had that a few times
2026-03-11 16:40:51
2
richardroebuckblu
richardroebuckblu :
Bad capacitor
2026-03-21 15:35:18
1
davedalerio
davedalerio :
Cool
2026-03-16 21:48:06
1
sagicorn1269
Sagicorn1269❌ :
Non factory “universal” Fairly new motor that was wired wrong
2026-03-01 20:41:26
1
mikeyw961
Mikey :
An AC motor is completely dependant or frequency for speed. So the only way that is possible is changing frequency
2026-03-01 03:59:42
1
eddeeew
EddeeeW :
What causes that crackling sound when the condenser shuts off, i have a carrier condenser that makes a loud crackling sound when it cut off, any idea what causes that.
2026-03-02 23:57:07
1
adam_18111
Adam :
was that a after market cu motor with the two commons?
2026-03-01 02:03:20
4
ronaldballard23
ronaldballard23 :
Are they variable speed?
2026-03-01 08:06:52
2
zackcoleman40
Zack Coleman :
I’ve had a compressor pulling high amps on start up and dropping voltage enough to cause the condenser fan to stop and start spinning backwards.
2026-03-01 14:54:28
2
saaf900
saaf900 :
that could be capacitor it's bursting volts for a bit
2026-03-04 16:08:57
2