@blince.hydraulic: Ever seen two hydraulic motors running completely out of sync? One spins fast. The other barely moves. The issue isn’t the motor — it’s how you connect them. Understanding series vs parallel can save you hours of troubleshooting. #Hydraulics #HydraulicMotor #Engineering #FluidPower #Mechanical #Blince #BlinceHydraulic #HydraulicSystem

Blince Hydraulic
Blince Hydraulic
Open In TikTok:
Region: US
Monday 04 May 2026 14:00:00 GMT
72946
1616
24
99

Music

Download

Comments

vikinginvietnam
Oledoledoffen :
This is wrong
2026-05-04 20:41:59
19
chance.reno
Chance Reno :
You've made multiple technical errors in this. Pressure is resistance to flow. The hydraulic motor does not operate on pressure. It operates on the volume of oil passing through the motor. I teach industrial hydraulics.
2026-05-06 14:29:19
3
69mudcrab
Mario :
no mate it still has pressure and works 👍
2026-06-20 03:24:23
0
gazza9262
Gazza :
you have not idea what you are talking about pressure is a result of a restriction and if you have ever worked on sugar cane harvesters they have a pump driving a 4 section motor which becomes a flow divider and then that oil goes on to drive more motors after that
2026-05-05 01:03:48
5
blince.hydraulic
Blince Hydraulic :
Good point. To be more precise: the pressure does not simply “disappear” after the first motor. In a series connection, the same flow passes through both motors, and the pressure drop across each motor depends on its load. The total system pressure must cover the pressure drop required by both motors. So the real issue is not “no pressure after the first motor,” but insufficient pressure differential for the downstream motor when the total load demand exceeds the system setting. Thanks for the correction — this is a better technical explanation.
2026-05-06 07:19:52
0
aas59233
Buckzy :
Add a flow divider valve… its what a spreader uses anyways for 2 spinner motors that got to turn the same speed
2026-05-06 03:03:48
1
richaughe
richaughe :
so you're not going to give a correct solution?
2026-05-07 15:11:06
0
missingpartsclub
Replacement Parts :
you need a flow divider in the system.
2026-05-06 14:56:33
0
petersdrempt
Robert Peters :
Second motor does not have back pressure in your example. It is the first motor that have the back pressure coursed by second motor. In series connected you will need double capacity to achieve same torque. Please go study first than try to teach
2026-05-05 13:33:50
1
keith.loomer
Keith Loomer :
Not pressure volume
2026-05-05 22:35:49
0
cypherjunk2501
CypherJunk2501 :
AI doesn't know squat
2026-05-06 08:57:52
0
wolfgangmuttly
Wolfgang Muttly :
So explain a stack unit and a blower motor setup. And what are you putting to motors together it should be a motor unit and a pump unit. Similar build but different on internals
2026-05-07 01:40:55
0
johnfelthersnach
johnfelthersnach :
🥰🥰🥰
2026-05-06 17:12:14