@globalpowerelectricians: Installing a Tesla wall connector, dedicated receptacle for garage, and main home surge protector. #electrician #tesla #sparky #electricianlife #electricalwork
Not trying to be negative, just trying to learn . That looks like 6 romex , which I thought had a 55 amp max , how are you able to have on a 60 amp breaker ?
2026-05-08 22:14:13
7
André Azevedo825 :
Just a reminder that inside an Electrical Metallic Tube (EMT) conduit, the use of Romex cable is not permitted. You need to use THHN wire instead, and in your case for the Tesla charger, it should be 6 AWG.
2026-05-08 23:45:59
33
Garrett J Lehmann :
Where’s the disco
2026-05-10 05:18:13
6
sgand2010 :
My man using 55 amp nm cable on a 60 amp breaker. Nice
2026-05-08 21:48:36
9
glenngregory1966 :
EV= junk
2026-05-09 17:50:21
7
Tyler Neal :
EMT not grounded? why not use a grounding bushing inside the TWC?
2026-05-11 02:59:06
5
Dmunoz :
With the patch too pa!? Sheeeesh.. Hope you put that in your price lol.. a little criticism tho work on your offset the coupling right before the offset could look more professional but good install regardless
2026-05-09 16:24:49
6
user4409431655928 :
Doesn’t level 2 chargers have a built in gfi. I read and heard, from other electricians , it will trip the gfci breakers? Just trying to be knowledgeable here
2026-05-10 13:48:58
5
Easyrecipes :
Amazing as always guys 🙌🙌🙌
2026-05-11 15:31:50
6
user5351264719471 :
Or just use MC and get the full capacity
2026-05-10 22:04:45
5
John :
Scribbled a lil red with a sharpie, yall can’t get some red tape on there, professionalism is gonna go a long way in growing your business, it’s the lil things trust me, home owners see that and shake there heads man
2026-05-11 00:51:29
7
jiuverballadares :
Great work like always.
2026-05-09 02:48:42
8
ZyraElectric :
Can’t use #6 Romex. It’ll melt. Gotta use THHN copper in conduit if you’re gonna send the full load. 48amp x 125%=60amp breaker.
2026-05-10 11:39:45
7
Mr Davis :
Good job brother
2026-05-09 23:00:26
6
Wavyyy 🦋 :
6/2 SE
2026-05-11 02:28:13
4
Elixim :
Wrong amigo !! No bueno
2026-06-14 05:52:45
2
Henry 202 :
Porque utilizas cable romexx en Tuberiaa emt
2026-05-10 02:42:17
8
Siva Subramaniam :
My electrician incorrectly ran romex for my emporia charger and I had him come back and change it to 6 gauge THHN.
2026-05-11 01:40:43
4
Trump 01 :
I would want my money back if I’m not getting the full power
2026-05-10 04:58:45
4
juliorocha0521 :
Can’t use romex 6/2 for 60 amp car chargers.
2026-05-10 14:27:35
4
Kyle :
wrong
2026-05-09 16:11:04
4
i.am.duane :
I’m digging how yall have the shirts with info on that…… like the long sleeve idea need to bring this up to our company
2026-05-09 11:54:58
4
DAXXHOMES :
Whoever is watching this video, please don’t use #6 NM cable for Tesla changer, obviously no permit was pulled, what code year are you on?
2026-05-09 20:07:49
5
Erasmo Vargas :
no sirve no pusiste los conectores en el panel saca otro contenido por q queda abierto se meten animales producen corto
2026-05-09 22:27:11
5