@kenendunwa: If you know what this breaker is called, drop it in the comments 👇⚡ #ElectricalEngineering #Changeover #CircuitBreaker #TechExplained #NigeriaTech

Kene Ndunwa
Kene Ndunwa
Open In TikTok:
Region: NG
Tuesday 12 May 2026 19:33:52 GMT
638049
10867
522
280

Music

Download

Comments

samuel.waithaka1
Samuel Waithaka :
changeover😂
2026-07-09 10:00:03
0
tams_energy_and_security
TAMS Energy & Digital Security :
Change over
2026-07-09 19:06:52
1
scobi_22
Engr Francis22 :
2p breaker already interlock
2026-07-09 19:14:32
0
gyanbismark515
O B K. GYAN you :
Tht is changeover breaker or interlock breaker
2026-07-09 20:43:39
1
mengshak.joel.nan
Mengshak Joel nandom :
it's Also known as automatic breaker
2026-07-09 21:07:58
0
quaisy_emma11
Quaisy :
It's an interlock Breaker mostly used as change over
2026-07-08 09:16:12
1
tobiishola55
DAMMY :
A single-phase interlock breaker is a safety device or mechanical interlock that prevents two power sources (typically the utility/grid and a generator or inverter) from being switched on at the same time. This prevents dangerous back-feeding and protects both equipment and utility workers.
2026-07-07 18:41:37
2
user35660691536160
THE MODERN ELECTRICAL EXPERTS :
it act as a manual change over. for example electrity can be connected to one DP and generator to the second DP. then you loop the lives and neutral of the two breakers on there outlets. At that point, load wire is terminated at one of the looping points
2026-05-13 09:44:43
370
nexajoule
NexaJoule Energy :
MTS (though this version is not "too" safe) Check the image, notice the mechanism in the middle which increases its safety.
2026-05-13 02:21:56
42
oh_yesug
urbane :
I think it's designed to supply both AC and DC supply. would I be right to call it a changeover breaker??? I stand to be corrected
2026-05-13 03:38:27
16
simonsilvr
simonsilivester :
it because of electro magnetism both of it has a magnetic
2026-05-13 18:48:01
7
aaliyan309
Aliyan💸 :
because this breaker design for change over if one will on and second will automatically off
2026-05-14 16:06:07
15
bamokelect.bm
Bamo k Electrical :
autho chanover
2026-05-13 06:31:13
14
sam_whyte
SAMUEL UGOCHUKWU :
The answer to the "Why" is because it is either electrically or mechanically interlocked.
2026-05-13 18:35:10
8
user92047824598151
Gravity electricals and solar :
interlocking
2026-05-26 14:27:40
6
stevest001
Stevest001 :
I’m not an engineer so this is my layman explanation🤷‍♂️….It’s used to supply power to battery, once side is PV while the other is from grid so the both are not suppose to on at the same time😏
2026-05-12 20:41:31
9
williamscashboss
CASH $ BOSS 💵💵💵 :
it's a change over system, when you are on generator and they brings light.. it will automatically turn off the generator power then you can switch to nepa, it can also work as an intermediate switch.
2026-05-13 21:21:01
8
meckcity_electrical
MECKCITY ELECTRICAL CONSULT :
It's manual transfer switch so the two cannot supply at the same time
2026-05-13 10:18:09
6
michaelbello35
Michael Bello :
changeover breaker
2026-05-12 20:13:05
23
yarefal
yaréfall🇲🇷 :
mecanic interlock
2026-06-15 23:11:54
1
marcjnmeyer
marcmeyer639 :
has interlock for safety
2026-06-03 14:16:44
1
mbaleelectricianslimited
Mbale electricians limited :
where can I get one?
2026-06-04 19:19:29
1
abelelectrician
ABEL ELECTRICIAN :
I wouldn't use this changeover
2026-06-03 11:11:50
1
mwanajaa4
Aamal Gael 🦋 ♥️ :
act as a manual changeover switch