@the.ship.electrician: Marine Electrician Life Ep. 33⚡ ⚠️ LOTO / isolate and de-energize the circuit before testing ⚠️ Quick troubleshooting check of a 230V AC solenoid coil using a multimeter. Measure resistance across the coil terminals. If the meter shows OL / Open Loop → the coil winding is broken and the coil is faulty ❌ For AC coils, resistance values can vary a lot depending on coil design, wire thickness, number of turns, power rating and inductance. That’s why two 230V coils may show completely different Ω readings and still both be normal. A multimeter measures only the DC winding resistance — not the actual AC operating impedance. #test #fluke #marineelectrician #solenoidvalve #coil @FLUKE Australia @Fluke Corporation

the.ship.electrician
the.ship.electrician
Open In TikTok:
Region: PL
Thursday 14 May 2026 16:19:08 GMT
50084
880
10
36

Music

Download

Comments

abc_56785
ABCD :
your video flash too fast. my eye and brain slow to digest
2026-05-27 06:01:59
2
bricee_13
Brice :
Bonjour merci pour ta vidéo ! Pourquoi tu rajoutes les fils ? Pour mesurer la résitance comme tu dis il faut couper le courant n'est ce pas ? Le test a etait fait sur une bobine de 230volt AC c'est sa sur du 24 DC cela ne marcherait pas ?
2026-05-15 08:43:23
2
gunny0042
TG :
prefer red gloves
2026-05-23 19:35:17
2
a8.khan0
Saad Ahmad :
ok
2026-05-15 16:44:25
0
eenjineer
rafi :
😳😳😳
2026-05-16 00:06:34
1