@awesomeframers: Tuning up the framing before drywall. Sawn lumber after multiple cycles of wet, dry, hear and cold can move quite a bit. Best to check right before drywall. @RR Buildings Toolbags getting some use. . . @ISOtunes code Timmy10 (Kyle has a code too)
thats a bearing wall. you need to do a double stud since you notched the shit out of that stud.
2026-05-27 15:50:35
6
G-038 :
You don’t have to cut it completely out
2026-05-27 01:41:44
12
caveman :
Pink hammer ?? wtf
2026-05-27 04:50:32
3
Vampire Alberta :
That would instantly fail inspection in my area.
2026-05-27 06:13:06
3
gator :
wires are never an issue.
2026-05-27 02:22:34
2
Ben Hayne975 :
shouldn't the blocks fit snug?
2026-06-11 10:54:51
0
Cosmic Ranch ID :
it's easier to high grade your studs. I've never thought twice about the straightness of a wall I've built (even a couple when I made mistakes) and nobody ever noticed
2026-05-27 03:49:01
1
L505 :
You should have only cut out 1 1/2 in. size of the 2x4.
2026-05-27 12:47:53
5
brianfrustaglio :
Do not do this. Thank you
2026-05-27 12:11:25
6
gary :
it's only a shed why does it matter
2026-08-01 18:11:38
0
myaba466 :
wtf????
2026-05-27 18:49:03
3
Bob H923 :
Can some one help me out. One stud is bowed in. He used a 5 ft level over 3 bays. That did not show the true plane of the wall.. Do we not use string lines or chock lines for planing any more. 😏
2026-05-28 14:26:09
2
chuckreardon2 :
Structural shear wall? Yeah, don’t do this.
2026-05-27 19:10:07
7
Briann0tBryan :
New nailer every video I see you in! :)
2026-05-27 00:49:18
0
user6835809859917 :
See nothing wrong with that. Nice way to improvise there. I like that fix. 👍
2026-05-27 01:35:10
2
Jimmy 🇨🇦 :
What we did was we cut a slot the width of a sawblade at about a 45° angle and ran a screw in there and that sucked the stud straight out that’s how it worked for us. I’ve never seen it done this way in the 45 years that I’ve been working in the industry.
2026-05-27 14:01:17
3
chango :
wrong
2026-05-27 13:16:39
2
Kyle Eagles :
I know some people cut studs on angle where ever its crowned to straighten before drywall (if non load bearring) this was actually seems much better to me
2026-06-02 13:57:18
0
PatrickpistolCotten :
banned
2026-05-28 04:31:15
0
user8331205629870 :
That's weird i've never seen a header for electric line
2026-05-28 00:36:59
0
TiredOfThisShit :
1) code fail
2) it's going to pull back in in about a week.
2026-07-22 14:58:28
0
troythomason0 :
No one would do this.
2026-06-07 15:05:12
0
Joker.0203 :
What are you doing man!!
2026-06-03 11:29:40
0
undercover :
thats not how you do that you need a board streacher
2026-05-29 13:44:44
0
David Schonacher :
Engineer letter incoming 😎
2026-05-27 22:31:31
0
To see more videos from user @awesomeframers, please go to the Tikwm