@letsbetechs: This is one of those diagnostics where just hearing the description pretty much tells you what the issue is. It's not super common because it depends on the system having a single-pole contactor, and the compressor has to ground out on the side of the contactor that's being switched—otherwise, it just kicks the breaker. Maybe it's more common for other people, but this is probably only the third time I've seen it in 27 years. I do hear others talk about it happening to them, though. How often do you see it? I didn't think about it while I was there, but I should have shown the amp draw coming through the white wire. There was no amp draw through the black wire, but we would have measured an amp draw across the ground wire since it's providing the path back to neutral. #hvac #hvacapprentice #hvactechnician #hvaclife
You should explain how that works. How didn’t that trip the breaker and why would that cause the fan to spin
2026-06-20 13:08:14
33
iphone2001 :
Had this pretty much happen on my first AC call of the year back in march. Definitely threw all of us for a loop but the compressor ended up being grounded
2026-08-19 00:30:41
2
Robert Spencer :
Honestly I thought it was a bad fan motor I have seen comp error
2026-06-20 13:08:29
8
jasonseufert420 :
Seen one do this once and it was the crank case grounded out.
2026-06-21 11:51:30
5
Donnie :
Throw a couple $100 Arco compressor in it and call it good.✌
2026-07-17 13:42:20
2
Paul_eric :
I’ve seen crankcase heaters do that a lot also that’s what I was hoping for but she’s gone
2026-06-24 21:16:26
0
Jacob Cruz :
One time I went to one call that was a second opinion for a bad compressor and I noticed that the outside fan kept going after I turned it off. Same thing bad contactor getting 120 to the top. But I was testing and the terminal from the compressor popped and lost the whole charge. First time seeing in person. And the homeowner was right there. Replaced everything.
2026-06-21 12:39:10
3
barrygeminiking👑 :
that don't seem correct how is the condenser running with a ground compressor?
2026-08-11 18:18:56
2
@J_Sil :
I have this exact unit, but mine is branded Evcon, my indoor unit is Coleman. I bought this house in 2019, unit is going on 23 years, still blowing ice cubes.
2026-06-21 12:37:31
2
shadowboxer65 :
Get some prices up to replace his whole system. Judging the age of the old unit? He got a good life from the Coleman unit. 😎
2026-06-20 19:40:30
1
jehovasthiccness :
I turned power on a system like that and it blew the charge through one of the terminals amh
2026-06-20 21:20:26
2
Q2The3rd :
I've seen them short to ground and keep running on 110v
2026-06-20 22:27:00
1
Menenic 🇨🇲 🇨🇦 :
Learning here thanks
2026-07-23 10:19:03
1
Jesse Horton :
I had a universal motor that had the reversing wires cut but the fan still came on when it was called. i was out there because the bearings were making noise.
2026-06-20 15:48:13
3
Greg :
Just had this on a Bryant
2026-06-20 13:05:53
3
Brascoe🛐♨️ :
I think a new AC is needed.
2026-06-20 22:24:31
1
DRSERVICEV :
it's time to change😁😁😁
2026-06-20 12:48:44
2
Q2The3rd :
ran up on this today. it needed a capacitor
2026-06-20 22:38:25
1
jake🇨🇦🇩🇰 :
So the grounded winding was acting like a path to ground, allowing the fan to run on 120v instead of 240v? Kinda like when you use a cheater cord to steal power for your vacuum pump or recovery machine
2026-06-20 14:56:57
7
Jason Raj Ramlochan :
❤️❤️❤️
2026-06-30 06:43:05
0
To see more videos from user @letsbetechs, please go to the Tikwm
homepage.