@jeredjoneshomes: who is this guy? and why did he installl an electric car charger on the side of my house? what gives, diy guy?
Jered Jones Las Vegas Realtor
Region: US
Thursday 25 June 2026 19:32:01 GMT
Music
Download
Comments
Blake Shelton :
Electrican here don’t do what he did
2026-06-27 14:48:42
344
Noah 🙋🏼♂️ :
This is unfortunate to see. That thing would fail inspection so fast for so many reasons.
2026-06-26 20:39:10
115
Barak Bryant :
Should of hired a electrician
2026-06-26 02:41:46
663
Alex :
That 90 connector is not water tight water will fill and rust inside of the pipe
2026-06-26 19:42:08
90
🪨🪨🪨 :
how would one replace a live outlet without turning it off
2026-06-26 04:29:03
24
⃟ :
if he actually got zapped by the panel he would’ve A been dead B been tasting colors
2026-08-21 22:58:14
5
user4889287476909 :
Will it work, yes. Is it code compliant, no.
2026-06-28 02:27:09
42
MZIRG 🪳 :
Contact your electricity company and see if they offer discounted charge rates overnight, they usually do and it will save you a lot
2026-06-25 21:51:35
60
Troy :
No, that phone didn’t overheat. There’s no way you fished that wire through that 90.
2026-08-01 20:43:13
5
ـــــــــــــــــــﮩ٨ـ❤️️ :
should of hired an electrician...
2026-06-26 18:39:55
53
myles_carpenter :
Never work on any electrical system while it’s turned on always confirm that an electrical system is dead
2026-06-26 10:13:14
9
ParagonPower :
not the hard 90 😭 lord have mercy
2026-06-27 21:03:53
16
GHOSTxKOD :
I like how the conduit is supported.
2026-06-28 00:40:54
20
Grant Thompson489 :
Your phone didn’t over heat you had to take that 90 degree off lol
2026-06-26 16:33:38
43
Blayne Schmidt :
Inspection nightmare
2026-06-26 23:26:05
22
jcs :
call an electrician bro
2026-06-28 16:28:44
12
chaotic_tsg :
Yeah, definitely not rain tight fittings…
2026-06-26 17:57:23
59
Aaron_Sparky :
Not bad for diy
2026-06-26 14:21:49
36
one 2 three 4 thumb 🤺 :
Why is no one talking about that panel? Being an interior panel used outside
2026-06-26 16:27:16
13
rocco salvoni :
“Nice and neat”
2026-06-27 09:56:09
12
CHaMoY ThE ShaRPei :
You used a indoor 90 elbow connector 😳
2026-06-28 08:17:51
9
TrivialBrett :
shocked*
2026-06-27 01:09:59
8
emk.edgar :
looks good other than that 90, you can get a short lb that might work or you might need to move the charger up and use a pre bent 90 from home depot
2026-06-26 06:09:42
8
Matthew Benjamin Nel :
That set screw connector isn’t out door rated
2026-06-26 02:21:21
18
CWOO96 :
I hope you used the correct wire type adjusted for ambient tempature
2026-06-26 20:31:13
11
To see more videos from user @jeredjoneshomes, please go to the Tikwm
homepage.