@spark.lab5: Why You Should Never Run a Single Live Wire Through a Metal Conduit💡⚡️ Like❣️ comments📋 Share📤 . #electrician #electricalwork #diyelectrical #electricalhacks #electricaltips

Spark Lab
Spark Lab
Open In TikTok:
Region: GB
Sunday 28 June 2026 11:41:07 GMT
68391
2216
29
188

Music

Download

Comments

piowear
piotr wasiak :
which is why we mostly use pvc in Europe it's also cheaper and more flexible
2026-06-28 13:54:43
11
bikeslip
bikeslip :
Aluminum conduit or AL flex conduit is okay. Single conductors can not pass through steel enclosures or lock nuts and only supply side is grounded so use aluminum plate on supply and insulation board on load side to prevent sheath currents. An old boy hack is to notch all KOs with saw blade so all three phases are encircled by steel if you don’t have aluminum
2026-08-13 20:45:18
0
warre250
warre250 :
Does a neutral always have current in it.
2026-06-30 02:21:56
2
emmaelect247
emmaelect :
As engineers, we should always remember that current flows through the live and returns through the neutral. A damaged or loose neutral can cause earth leakage and electric shock hazards. Thanks, Engineer, for sharing this valuable knowledge.
2026-07-02 07:15:14
3
crinklecut68
CrinkleCut :
the basis of time travel
2026-07-19 00:24:01
0
brigadeaeddie
Eng Brig. :
I just learned different content 😅
2026-07-04 15:14:09
0
wawaysy
Stewart Sy :
how about DC?
2026-08-13 00:11:47
0
totosdad
totosdad :
Very interesting, thanks
2026-06-29 02:11:24
1
clona_manifold
CLONA Manifold :
interesting fact. 👌
2026-06-29 05:29:39
1
osbourne_top_tradesman
OSBOURNE Solar/Electrical/AC :
ok
2026-06-29 12:14:13
2
chappo564
user8782692961542 :
Eddy
2026-06-29 16:12:48
2
youngelectrician6
Young electrician 🧑‍🔧 :
this is very interesting topic
2026-07-05 06:09:07
0
nirala.kanxa
Nirala kanxa :
Yes Eddy current is harm ful on Metal conduit .
2026-06-28 22:52:33
6
leejansen5
Lee Jansen :
iuuer y is ti live
2026-07-17 19:49:12
0
red.observer
Red Observer :
So you're saying the wires required inside a metal conduit require a going and returning wire? So 2-4-6-8-10 where equally going and returning ratio of wires?
2026-07-01 12:09:33
1
grahamturner75
pluto :
I hope the wires aren't hot
2026-06-28 11:56:43
1
james.toh89
James Toh :
3 phase sometimes doesnt include neutral for motor operations. What then?