@suzy__2xx: When you go through The Home Depot for your “fencing” & they contract it out to another low down company! This is what ya get 🤭 THE HOME DEPOT OF CHAMPAIGN IL AND PEERLESS FENCE FROM BLOOMINGTON IL ARE FRAUDS. Please be careful out here! #thehomedepot #peerlessfence #fypシ゚viral #fypシ #Peerlessfenceandsupply

Suzy__2xx
Suzy__2xx
Open In TikTok:
Region: US
Thursday 02 July 2026 23:36:08 GMT
635740
7659
906
386

Music

Download

Comments

xihua84
J :
This is why service wires should be in conduit.
2026-07-03 11:22:24
2427
melkel18
Melkel18 :
Who ever laid that wire, never got it inspected
2026-07-03 10:53:50
697
itslobbyp
libby :
Is that why I didn’t have wifi for 2 days
2026-07-04 22:38:01
1
nate.be.fishin
Nate Be Fishin :
whoever laid the wire messed up. not the guys that installed the fence. wire isnt at the right depth and doesnt have conduit
2026-07-03 11:31:10
1616
djmorr007
DJ〽️ ×̷̷͜×̷ • Friends :
Electrician here, easy fix
2026-07-03 16:27:44
37
eddietech27
LALO :
I’m just saying but any high voltage wiring or service lines should be in some sort of conduit about 18-24 inches underground.
2026-07-03 03:28:23
281
jessepiinkmon
Capncook :
As a fence builder, we do not give a fuck lol
2026-07-04 00:03:15
12
manimal580368
Chris :
You can still see some red paint too so it was marked and they didn’t care.
2026-07-03 00:25:37
251
waffles4danimal
waffles4danimal :
they should have contacted JULIE
2026-07-03 02:42:22
17
suzy__2xx
Suzy__2xx :
I was without power in 90 degree weather because of this companies negligence!
2026-07-03 02:09:53
23
mpb22576
mpb22576 :
well first off it’s not even close to being at depth and why are we running service wires not in any type of conduit wow
2026-07-03 04:07:16
117
renewed.apostle.of
Renewed Apostle of Jesus :
why are service wires less then a foot under ground?
2026-07-03 11:51:17
9
crackersunited2
Crackers/United#2 :
Your service should be way deeper than that. Also should have warning tape.
2026-07-03 11:45:36
12
dan.does.mma
Dan does MMA :
Everybody is getting worked up but it ain’t that deep
2026-07-03 16:17:42
15
mark471100
Anderdingus :
Why the hell are the service wire not deeper ? Atleast 3’ depth smh
2026-07-03 14:20:15
2
itsschotty
Jeremy Allen Schott :
happens all the time.
2026-07-04 12:05:52
1
neko3269
Sir Neko :
lol, where’s the schedule 90 pvc🤣
2026-07-03 23:02:54
1
dragonwings78
˚‧。♥。‧˚Dragonwings‧。♥。‧˚ :
Did they not call JULIE?
2026-07-03 19:53:29
0
braydan.mains
Braydan mains :
Why is your service cable only like ke 18 inches deep😭
2026-07-03 05:50:26
25
a.robb8
a.robb8 :
Electrician here. This is a non issue, wire is too shallow and not in conduit. They had no other option unless you wanted to trench your entire yard and rerun the wire.
2026-07-03 12:38:32
11
yotb01
yotb01 :
Those service wires are ridiculously shallow.
2026-07-03 16:18:59
20
forever.the.og
Dr. Doom :
That's definitely not up to code. Fence installers aren't to blame
2026-07-03 11:43:02
116
joytime75
joytime75 :
Not a chance that service is 3 feet
2026-07-04 03:36:48
9
bsirm
Bsirm :
That’s not on the fence guys
2026-07-03 18:01:21
98
james.garcia03
SamVerona :
why are service cables 6" deep??
2026-07-03 13:58:59
136