live loads because their weight changes with water usage. changing from emptiness to fullness
2026-07-06 04:53:56
5
ONSONGO BRIAN :
water tanks together with their contents are considered quasi permanent loads therefore considered dead loads. though the designer should design for when full and when empty since they have different impacts more so when designing for wind.
2026-07-06 20:00:40
2
Rev Nehemiah M Rugiri :
dead loads def
consider the stress of water to be always there,
same load out same load in.
2026-07-08 09:53:55
0
The Guide. :
I'd take it as dead load and design at full capacity...the water only varies interms of capacity but it's not moving... it's still
2026-07-06 07:07:17
1
user120625497054 :
They are dead loads because they were incorporated unmovable loads to endure so long as the building endures
2026-07-06 06:48:22
0
DEX | CIVIL ENGINEER :
Self weight of the water tank should be considered dead load while the water should be considered live load
2026-07-07 18:54:35
0
Authenticity :
I don't even factor water load because it is known..
2026-07-07 16:39:24
0
Deep Man :
informative
2026-07-06 05:06:02
0
simpli.muhiaaa🎯🇰🇪 :
those are live loads if the columns were designed without them in mind but if stipulated during design then they are dead loads
2026-07-06 16:12:50
0
user 2h112 :
what about the vibration when the water Rush in
2026-07-06 08:04:43
0
xxx :
For me it needs to be considered as live load as they vary during the service period of the building. Thanks.
2026-07-06 06:52:28
0
The Landlord :
They are live loads because the loads keep changing with varying water levels
2026-07-06 08:30:59
0
BMK Engineering & Const. Ltd :
variable fixed
2026-07-06 07:31:17
0
T_kiptoo :
They are considered dead loads because their maximum load does not change.
2026-07-06 07:15:37
1
PEGMA ENGINEERING COMPANY LTD :
I think when designing , we design for full capacity tanks.. and design as dead loads
2026-07-06 05:51:04
0
xanaqaye :
Unmovable load is called dead load
2026-07-06 04:16:32
0
dedankmugambi :
Dead load because maximum capacity is know they are designed to be refilled continuously to facilitate continuous water supply. Picture them like wc cistern. The water refills immediately after flashing
2026-07-07 09:22:24
1
Look :
They should be considered dead loads because they get full. Their load should be taken at the max weight.
2026-07-05 20:10:09
3
Cyp :
Enginering exam inakungoja...are you asking engineers ama ticktockers😁
2026-07-08 01:14:30
0
simon kimani :
🥰🥰🥰
2026-07-07 12:00:59
0