@civilengineeringtip: If your column size reduction necessitates a 10 cm shift, the crank length must be at least 60 cm to meet the 1:6 ratio. If the co space does not allow for a 60 cm transition, you cannot simply bend the existing bars; you will need to provide lap splices with dowel bars instead.