@ferrus_electrical_ltd: Electricians are more than just people who run cables. ⚡🏠 From the kitchen layout to the positioning of sockets, switches, appliances and lighting points, proper electrical piping has to be planned with both functionality and aesthetics in mind. At Ferrus Electrical Limited, we don’t just install electrical pipes—we consider how the finished space will look and how everything will work together. Yes, electricians are also interior designers in their own way. 😉⚡ Good electrical work starts from the skeleton stage. 📞 0805 270 3366 📩 Send us a DM to discuss your project. #FerrusElectricalLimited #ElectricianInEdoState #ElectricalInstallation #ElectricalWiring #KitchenDesign
This is 2026 Bro, u need to upgrade.
* 6×6 COOKER UNIT is Old fashion
* 15amh Socket & plug is old too
* Everything is 13ahm nw
* Mostly all the home appliances are nw smart & Energy Saving.
But u try though.
2026-08-16 10:57:56
15
King k kings :
Bro u don’t use cooker and other appliances same pipe.differentiate the pipes.the cooker alone is too heavy to hv same pipe with other appliances
2026-09-30 17:32:09
1
B R T :
this is old version bro try to upgrade. I don’t use that here in lekki.
2026-08-15 09:44:29
8
PPL ELECTRICAL COMPANY👷🏾♂️ :
Okay there’s nothing new here, just normal electrical Kitchen piping. Next time use Grid switch to safe yourself the stress of mounting sockets up and down the kitchen... Gracias ✌🏾😎
2026-08-14 12:15:17
14
ClassicDonj :
why didn't you introduce smart switches for the fridge, oven and microwave
2026-09-07 20:16:17
0
💎༒︎𝓗𝓞𝓛𝓐𝓡𝓙𝓤𝓑𝓐༒︎💎 :
u supposed to bow out single 25mm pipe for the cooker pipe
2026-08-14 21:44:15
5
Kadienergy :
What are you using 20A switch for in powering on extractor?
2026-09-16 13:21:13
0
olamilekanabeeb54 :
you try, but that your cooker unit under extractor is wrong❌
2026-08-15 05:55:59
0
CHISOM" 🤍❕ :
That's cool 😎 man✌
2026-08-15 09:29:48
1
simo37 :
u need to change the cooker switch bz the water vapour from anything u cook it will enter in the cooker switch u fix it away or aside your cooker position
2026-08-19 15:15:20
0
WHAT MUST BE DONE MUST BE DONE :
u forgot to put AC in that kitchen
2026-08-28 07:44:33
0
uchenna Jeremiah Francis :
you would have not share wicrowave and ovun same,why not different?
what if both are on same time?
2026-08-27 05:07:06
0
smartek electrical :
Using iron box in 2026 ?,
2026-09-07 11:05:02
0
UC_ELECTRICAL_EXPT. :
Try dey use building plan
2026-09-16 21:06:35
0
Engr Daramola T S :
this is old kitchen writing
2026-08-25 08:32:02
0
Eric moni :
This is old pattern you how can you use one 20mm pipe for cooker and the heat extractor
2026-08-20 02:36:43
0
Pa Chi Tech :
Thank you engineer for a good job.
But there is no general Rule for this, just look at the house blueprint or ask the owner the design, then you follow the owner's preference
2026-08-16 11:40:44
0
Dami J :
that means you are doing half condite
2026-08-14 17:27:41
0
ObtechElectrical :
the cooker should work together with extractor
2026-09-01 14:45:07
0
ÂSK ÔF FÛTÚRÉ 🗽 :
Can one pipe contain the whole wires both cooker and extractor why not separate them boss
2026-08-16 05:36:23
0
Aduragbemi Joseph :
What about tv socket and air conditioner. Next time use 3*6 socket not 6*6 hun
2026-09-24 05:21:49
0
ayomajeed :
You really try but trust me this is the old version of kitchen design
2026-08-15 06:28:20
0
ķïñğ__ pħǎřãøħ😈👹 :
Boss you sabi work 🥰
2026-08-16 06:04:35
0
X-Murphy Medo :
so what if the owner of house no come get all these things.
2026-08-15 08:07:39
4