@sixfigurefingers: 🚨Blown Fuses🙏I Know Its Something Bad ⚡️⚡️⚡️#bluecollar #ELECTRICIAN #fypシ #FYP

RickyRickChavez
RickyRickChavez
Open In TikTok:
Region: US
Tuesday 18 August 2026 21:04:28 GMT
48728
4402
99
85

Music

Download

Comments

chieftawny
Chieftawny :
If it’s a constant problem, why not install breakers?
2026-08-20 11:07:00
4
danielguardado4
Daniel G :
What conductive fiber ? Please explain.
2026-08-25 19:42:50
2
foltenbankzz
foltenbankzz :
I use ohms when checking my fuses
2026-08-18 23:03:38
32
a.b.m.bowling
A.B.M. Bowling :
Why didn’t you ohm it?
2026-08-19 10:25:02
14
dan1776_
Dan b :
Dumb question but why are you checking a difference in potential and not continuitty
2026-08-19 21:07:59
16
chasethemighty
Chase Boudreaux :
Wouldnt it be better to go to the bottom of the fuse terminal to ground? Lets say you had no supply voltage all fuses would check good like this
2026-08-18 22:20:27
17
wonderbread51502
WONDERBREAD5150 :
I assume that panel is more than 50v so wouldn't replacing the fuse not fall under troubleshooting and you are supposed to Lockout the panel? not saying you are in the wrong, just a genuine question.
2026-08-19 08:12:02
3
jeffreyi724
Jeff :
Now a video on different types of fuses and why all 10 amp fuses aren’t the same
2026-08-18 22:35:00
5
kyliewylie561
kyliewylie :
Must be a grounded delta transformer if you have 460 on a single leg
2026-08-19 01:58:23
2
crispy023
Randy Miller1353 :
um... difference in potential and the way the meter works at some point the secondary sode of the fuse would need a reference to ground, is the whole building a corner grounded delta?
2026-08-19 00:58:21
4
c7pizzon01
AB :
why is that there is voltage when fuse is blown and vice versa?
2026-08-19 01:13:40
3
andersoncj87
CJ :
I get this way as well. I normally start by putting one on ground and one on the bottom of the fuse block.
2026-08-19 17:26:28
6
captain_greybeard
InA3dWorld :
We had cabinets in a dirty environment and what we did was pressure it with clean dry air. Plumb it in with a regulator with like 10psi and kept all that mess from going in.
2026-10-05 15:57:30
1
adavis8652
Albert Davis :
That’s ideal; however, for the best reading of the fuse, you should pull it and check with an ohmmeter.
2026-08-19 04:22:24
3
kridthekidd92
kridthekidd :
My teacher said you’re supposed to cross check fuses, not top and bottom
2026-10-02 22:55:23
1
alexander4_20
Alex Flores :
Don’t forget both probes on the same hand my brotha from another motha
2026-08-20 16:34:50
3
e.a.c.h.one
DeeAlvarez❌️ :
Yesterday we spent four hours troubleshooting from our oil mist station pressure switch, back to the relay, and fuses only to find out the operator did not have the mill in Run mode. smh.
2026-08-21 18:37:52
2
jaycup13
Jaycups :
cool videos man. I was thrown into maintenance without any experience on my 3rd year of it and these videos help alot
2026-08-27 17:23:31
2
john_1182
john :
I feel like I just made $220 bucks just watching this
2026-10-06 08:37:16
1
trav2048
Trav :
fuse blocks with indicator lights save so much time when troubleshooting a bank like this.
2026-08-29 15:50:12
1
teejayy_09
TJ :
Could just check the outfeed side to ground,
2026-08-18 23:04:25
3
jackallen530
Jack Allen :
Difference of potential? I guess I learned something I go bottom of fuse to ground. After I check in coming power.
2026-08-19 11:07:13
2
geogat2723
Juan Brady :
Going load side of the fuse to ground is the most common way to troubleshoot, but to each is own... as long as you find the problem
2026-08-20 07:31:07
1
starluxy7
Yosoyluxy :
nice content bro
2026-08-19 05:27:19
1
biggucciejay
Elias🧊 | EBS services ⚡ :
you made me understand difference in potential. thank youbro
2026-08-19 12:51:44
1