@mauro_hvac74: Side discharge #hvac #sheetmetal #tinknocker #bluecollar

mauro_hvac74
mauro_hvac74
Open In TikTok:
Region: CA
Friday 21 August 2026 14:05:44 GMT
23096
482
111
21

Music

Download

Comments

frigoriste74
Frigoriste :
5 ton unit delivering 3 tons
2026-08-23 03:48:46
0
blake3ddesign
💎Blake 👑 3-D Design🫆 :
That transition should’ve been longer my God air restriction you guys are gonna have problems with that unit for life
2026-08-21 23:51:04
35
whichoneswhich
whichoneswhich :
curb adapter shortage i guess
2026-08-23 00:18:33
0
user760258133180
mill :
trans.sould be a little longer
2026-08-23 01:47:36
1
jeffmontalvo529
jeffm :
if only those removable panels were made for side discharge applications...
2026-08-22 14:48:39
6
dcp360
DCP360 :
I remember the first time I detailed exposed ducting………🤡🤡🤡
2026-08-22 22:44:37
0
joe_bidden123
Ludakuu :
Out of all these comments, I’m the only one that caught this, looks like the supply was was mistaken for the return so he had to put transitions in there
2026-08-22 15:39:27
1
rickydenniss
Dennis the Menace :
whoever designed that should be fired
2026-08-21 19:00:55
18
churchy09
Churchy :
holy choke hold batman
2026-08-22 17:05:17
0
monstersayen2
user7578280471021 :
For every 1” of change on SA you need 7” and return air is 1 “ of change you need 5” ,you have cooked the unit that static pressure will affect the head pressure and air flow this units will burn out sooner than later! Border brother air go!
2026-08-21 23:15:16
5
brizzle069
CheifQueef :
Bruh, the whole line is brand new 😭 you CHOSE to make the transition so small 😂
2026-08-22 01:47:18
14
user4148426566500
user4148426566500 :
How NOT to install a rooftop unit
2026-08-21 20:10:48
13
whomejusthangnaround
Old school217 :
Oh lordie
2026-08-22 20:54:53
1
the_only_c_los
C-Los :
Looks good only thing I would have done differently is make that first transition longer, it will restrict air flow
2026-08-21 23:59:48
6
ebenthomas869
ebenthomas869Eben :
that's good looking work, yes flex connections are fine. transitions look great good job. these other comments show their lack of field knowledge.
2026-08-21 22:29:26
0
jg19741
JG19741 :
why dont use the side panels on the roof top unit ?
2026-08-22 03:26:58
6
someguy0850
thatguy :
might as well have put two end caps back to back, choked that down 50% 😂
2026-08-21 19:30:53
5
axel.sevilla44
axel sevilla :
Thanks to show us how not do it
2026-08-22 14:12:03
2
joshuatilson4
Huua420 :
it's almost like there is a better spot just above there, that is ment for that
2026-08-22 14:12:39
3
inventz4
inventz :
The “Air don’t care neither do I” crew.
2026-08-22 04:34:51
2
dstar761
dstar :
Yeah all the comments are right. You should never shrink a fitting below 18” in cases like this
2026-08-22 18:11:48
1
orellan88
Horacio orellan :
Smacna is crying but it looks nice tho
2026-08-22 01:14:02
1
bigboypawpaw
pawpawlp1956 :
why flexible connections in the weather
2026-08-21 20:52:56
2
music_is_therapy1979
MUSIC IS THERAPY :
Good lord those transition 🤣🤣🤣 so much room to make it longer lol
2026-08-22 01:47:49
1
gualo89
Gualo :
transitions are way to short homie
2026-08-21 17:53:12
2