id put a shutoff valve on each of the segment, so that if for whatever reason one of them fills faster you can shut it off when it's dine
2026-08-24 02:12:07
52
user2659654596503 :
Feed from center
2026-08-24 04:37:49
10
StpdGmsStpdPzs :
What about just adding valves.. 😳😳
2026-08-24 08:24:50
2
Darren Martinez105 :
you need to create a loop on your main supply to create balance fed from side to side
2026-08-26 18:58:35
1
jay :
You are definitely going to need a vale on each
2026-08-24 11:45:10
2
bigharrybõlz :
reduce the outlets and maintain a constant pressure. low pressure irrigation system... just saying
2026-08-24 02:25:29
4
Scooter3262 :
To truly dial it in under pressure you need a flow control valve on each line…..you will see pressure drop across each outlet once its under pressure
2026-08-24 19:44:45
4
Bad Vader :
Head is going to have more pressure than the tail end of your line, with an increase in volume when installed is going to change your flow. Anyone who has ever ran gates pipe in a field can testify to that problem.
2026-08-24 14:09:08
6
astronawf :
Head loss will likely make each tank down the line fill slower than its upstream neighbor
2026-08-24 19:56:09
2
James :
Pressure compensating bubblers from irrigation could be your friend here. Cheap and way less finicky.
2026-08-24 16:21:35
1
Rabbit :
On my 300 I put a riser and a mixing valve so I only had to flip one lever. Filling and cleaning at the same time is the best.
2026-08-24 15:06:45
1
MJPworkshop and aquariums :
I’m actually so excited for you! I loved every single moment of my build!!!
2026-08-24 14:36:09
1
brandonsampson123 :
You have found common sense 😶
2026-08-25 00:13:35
1
Mike :
Could not see the very end of the manifold but if you have about 6-12 in of pipe capped at the end it will create a dead head and will allow to balance automatically. It wouldn’t matter where the inlet is. Inlet could be anywhere on the manifold.
2026-08-24 09:45:33
1
jefferygardner1 :
Or start from the middle but still need to downsize from 2 inch. 2 to 1.5 1.5 to 1 1 to 3/4 From end out or middle out.
2026-08-24 04:07:35
2
☆RayAndCharles☆ :
how cool
2026-08-26 11:13:12
1
JQT :
A loop on the feed going to each end would create a more even flow.
2026-08-24 12:28:44
1
Jaredhowitzer :
Do not glue the last 90 so you can turn it pointing up to divert flow away.
2026-08-24 12:41:18
1
bojangles4205 :
Absolutely love it
2026-08-24 11:26:38
1
Lypan💔 :
That will now work.You need to regulate each one of the pipes
2026-08-24 09:42:32
1
mjb8890 :
3/4 more pressure its not goin to balance easy i think anyway
2026-08-24 01:10:01
1
jefferygardner1 :
downsize from the 2 inch 1/2 every 10 ft you'll have more than enough for a balance load.
2026-08-24 04:03:45
1
doug :
are there overflow drains? if so why does this matter? why not use irrigation lines
2026-08-24 13:10:00
1
jimbyrnes916 :
creat a loop than you tees
2026-08-24 03:49:39
1
Cristian ogaz :
You should feed it from both ends
2026-08-24 02:51:25
3