@solcrestinc: Parallel pumps — will it work? Yes. Three things need to happen: 1. Same pump. One discharge pipe means one pressure. The weaker pump can't beat it, so its check valve never opens — motor running, nothing delivered, water heating inside until the seal fails. 2. Resize the suction pipe. It was sized for one pump. Two pumps pulling through it means higher velocity, higher friction, lower NPSH available — cavitation, and everyone blames the pump. 3. One check valve per pump. Not one on the header. Otherwise the idle pump backspins on reverse flow, and starting it that way takes out the coupling and shaft. Even with all three right, there's still the balancing — equal pipe lengths and fittings to each pump, header sizing, suction spacing, matched start/stop control. That's a design job. Is anyone running shared headers? Yes — it's standard. Packaged booster sets ship that way from the factory. Chilled water and condenser water plants. Fire pump rooms. Refinery and power plant cooling water. Boiler feed, transfer, sewage lift stations. The codes assume it: Hydraulic Institute covers parallel operation directly, API 610 / ISO 13709 requires a continuously rising curve to shutoff for stable parallel operation, NFPA 20 includes provisions for multiple pump units in parallel. So why can they do it? Because they can measure it. Test bench with calibrated flow meters on every branch. Pressure transmitters. They run the set and see the actual split — 52/48 — then correct it. Thermal imaging for the pump running hot. Vibration analysis for the one off its curve. Balancing valves with test ports so a commissioning engineer can trim each branch until they match. Manifold built on a jig, not fabricated on site. Pumps supplied as a matched set from the same production run. On site, you have one pressure gauge. You can't see how the flow is splitting. You won't know anything is wrong until a seal fails eight months later — and you'll blame the seal. So if you're doing this yourself, take the simpler route: line up a separate pipe for each pump — own suction, own discharge, nothing to balance. Or run it as a simple duplex — one pump working, one on standby, alternating. Never both at once. The difference isn't whether parallel works. It's whether you can measure it. Ref: ANSI/HI 1.3 & 9.6 series, API 610 / ISO 13709, NFPA 20. Cite your edition. Centrifugal pumps only. #pumps #centrifugalpump #API610 #NFPA20 #cavitation
Engr. Bhadz of SolCrest Inc.
Region: PH
Tuesday 25 August 2026 09:06:37 GMT
Music
Download
Comments
matematikoi :
gumagana, ganyan gamit namin supply papuntang feed tank ng boiler. may water softener pa
2026-08-25 10:31:27
0
JustfukinReal :
Sir, Pano naman kung naka series ang pump? May additional discharge flow rate kaya na mapoproduce? One of the example na nakita ko sa barko namin is yung supply pump ng liquified ethylene gas. thank you sirss...
2026-08-25 09:27:44
4
williamwallace0320 :
pero may instance ba na magkaiba ang pressue ng pump??
2026-08-25 10:33:10
1
Strawbarry :
what if sir may individual suction yung dlawang pump instead of 1 suction
2026-08-25 17:46:34
0
Infused Taste :
This is usual configuration in our plant.
2026-08-25 18:54:47
0
Sw33tpOtatos :
pwede yan.. basta hindi sila sabay aandar.. salitan..
2026-08-25 10:32:47
3
KaTech :
thanks for sharing engr.
2026-08-25 22:05:31
0
Juan Pablo Ortega :
Uso na ngayon variable speed
2026-08-25 15:52:10
0
escape.route21 :
👌👌👌
2026-08-25 09:25:16
1
realyouwell :
Do you have online courses po?
2026-08-26 00:57:31
0
J shok :
gagana po yan sir kahit apat pa na pump yan marami yan dto saamin sa process plant.as long as ung direction ng discharge ay iisa.😁ung picture na pinakita mo is para sa fire protection mga hydrant pansin mo ba sir na diesel driven at electric namn po ung isa..hindi po pwede na sabay yan...may jockey pump pa po yan .😁😁😁
2026-08-26 00:05:11
0
Account not found :
hi sir graduate po ako ng bachelor of industrial technology major in power plant, can i work po ba sa power plant kahit hindi engineer or cpm ?
2026-08-25 12:34:04
0
Syete :
ganyan pump pinapaandar ko boss 55hz yung isa tas 40hz yung isang pump
2026-08-27 00:34:21
0
bobot :
thank you sir sa libreng aral fallow po kita
2026-08-25 21:13:44
0
StubbySynthesis :
may issue sa amin similar ganyan.. return ng GENSET and main engine inisa lang papuntang fuel tank..
required kasi sa BV na Isa lang ang pipe papuntang fuel tank..
eh Sabi ng technician dapat separate ung dalawa..
2026-08-25 11:18:59
0
engr.aaaaaa98 :
Husay, Sir! Bigla kong narealize yung factors sa Bernoulli’s principle during explanation.
2026-08-25 09:20:20
1
sentai :
Gagana yan meron akong 3 identical positive displacement pump kasi ambaba ng flowrate ko para sa design ng thesis. Gumawa ako ng 3 inlet 1 outlet manifold nag 3x flowrate 😁. Though small scale thesis lang
2026-08-25 12:18:39
0
ria_san :
ganito dapat ang mga content astig,
malaking tulong for design engrs po
2026-08-26 10:14:22
0
quagmire1224 :
eh kung naka closed loop control at vfd 🤔
bale ang purpose nung control is masigurado na parehas ang discharge pressure
2026-08-28 02:40:09
0
@DMn2016 :
Yes madalas masunogan ng motor yung client ko sa ganyang set up.😳
2026-08-26 15:35:05
0
⚓LECKY⚓ :
back up pump po yan..
2026-08-27 01:40:35
0
Yka_angela :
ano ba advantage nya sa single pump?bat hnd nalng po bumili ng mas malaki na pump para mag katulad sila ng lakas ng 2 pump setup
2026-08-25 16:28:55
0
MG :
gagana pa din same pump kahit may pressure difference basta over size ung discharge manifold
2026-08-25 12:23:01
0
Master_J :
As a professional na engr, do you think may overlapping na din course niyo sa ibang course? And ano say mo dito engr?
2026-08-25 12:10:17
0
Noslen butete :
di ba yan magkakaroon ng turbulence sa suction side na mag cause ng cavitation?
2026-08-25 10:04:36
0