@yu.yu.maw872: @myat83270 ကို အကြောင်းပြန်နေသည် #🙏

Yu Yu Maw
Yu Yu Maw
Open In TikTok:
Region: TH
Friday 28 August 2026 06:39:40 GMT
3994
163
4
3

Music

Download

Comments

ko.zin22013
zin oo :
ဝယ်ခြင်လိုဖုန်ဆက်ပိပြောရလာ
2026-09-09 03:10:53
1
ko.zin22013
zin oo :
ဝယ်မတပ်လိုညီမ
2026-09-09 03:11:15
1
user922983128162
အချိုရှင်ချင်း :
🥰🥰🥰
2026-09-11 04:00:01
1
To see more videos from user @yu.yu.maw872, please go to the Tikwm homepage.

Other Videos

Understanding Variable Frequency Drive (VFD) connections is essential for reliable motor control and automation troubleshooting. This schematic illustrates a complete setup for a Delta VFD-EL controlling a 3-phase AC induction motor. Key Wiring Breakdown  * Main Power Supply Input: 380V 3-Phase power feeds into the top main line terminals (R, S, T) through a circuit breaker (-QF) for overcurrent protection.  * Motor Output Power: Terminals U, V, W connect directly to the 3-phase electric motor terminals.  * Frequency / Speed Reference: A 3-terminal Potentiometer is connected to 10V (Power supply), AVI (Analog Voltage Input 0–10V), and GND (Ground) to adjust motor RPM manually.  * Digital Inputs (Control Switches):    * Forward Pushbutton: Connected between M0 (Multi-Function Input 1) and GND.    * Reverse Pushbutton: Connected between M1 (Multi-Function Input 2) and GND.    * Stop Pushbutton: Connected between M2 (Multi-Function Input 3) and GND.  * Dynamic Braking: A Braking Resistor connects to terminals B1 and B2 to dissipate regenerative energy during quick deceleration or stopping.  * Status & Alarm Indication: Multi-function relay output terminals (RA, RB, RC) power a Warning Light Tower to display drive operational status or fault conditions. Pro Tips for Installation  * Always separate low-voltage control signals (potentiometer/pushbuttons) from high-power line cables to prevent electromagnetic interference (EMI).  * Ensure proper grounding for both the drive enclosure and the motor chassis to maintain safe operation.  * Double-check parameter configurations (such as source of frequency and operation commands) to match external wiring logic before powering up. #Automation #ElectricalEngineering #VFD #DeltaVFD #MotorControl
Understanding Variable Frequency Drive (VFD) connections is essential for reliable motor control and automation troubleshooting. This schematic illustrates a complete setup for a Delta VFD-EL controlling a 3-phase AC induction motor. Key Wiring Breakdown * Main Power Supply Input: 380V 3-Phase power feeds into the top main line terminals (R, S, T) through a circuit breaker (-QF) for overcurrent protection. * Motor Output Power: Terminals U, V, W connect directly to the 3-phase electric motor terminals. * Frequency / Speed Reference: A 3-terminal Potentiometer is connected to 10V (Power supply), AVI (Analog Voltage Input 0–10V), and GND (Ground) to adjust motor RPM manually. * Digital Inputs (Control Switches): * Forward Pushbutton: Connected between M0 (Multi-Function Input 1) and GND. * Reverse Pushbutton: Connected between M1 (Multi-Function Input 2) and GND. * Stop Pushbutton: Connected between M2 (Multi-Function Input 3) and GND. * Dynamic Braking: A Braking Resistor connects to terminals B1 and B2 to dissipate regenerative energy during quick deceleration or stopping. * Status & Alarm Indication: Multi-function relay output terminals (RA, RB, RC) power a Warning Light Tower to display drive operational status or fault conditions. Pro Tips for Installation * Always separate low-voltage control signals (potentiometer/pushbuttons) from high-power line cables to prevent electromagnetic interference (EMI). * Ensure proper grounding for both the drive enclosure and the motor chassis to maintain safe operation. * Double-check parameter configurations (such as source of frequency and operation commands) to match external wiring logic before powering up. #Automation #ElectricalEngineering #VFD #DeltaVFD #MotorControl

About